4207 -- System Performance Characteristics of a Helical Rotary Screw Air-Cooled Chiller Operating Over a Range of Refrigerant Charge Conditions PDF

4207 -- System Performance Characteristics of a Helical Rotary Screw Air-Cooled Chiller Operating Over a Range of Refrigerant Charge Conditions PDF

Name:
4207 -- System Performance Characteristics of a Helical Rotary Screw Air-Cooled Chiller Operating Over a Range of Refrigerant Charge Conditions PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper presents a study involving the operation of a 70-ton helical rotary, dual-circuit, air-cooled chiller while three independent variables are experimentally altered. The independent variables included in the study are refrigerant charge level within the chiller plant, outdoor air temperature, and percentage nominal chiller load. This paper examines the effects of the three independent variables on superheat and subcooling temperatures, chiller kW per ton, chilled water set-point temperature control, and compressor suction and discharge pressures. After analyzing the significance of refrigerant charge, outdoor air temperature, and percentage nominal chiller load on the operation of a chiller plant in an actual building, the consequences of refrigerant undercharge or overcharge are fully investigated and documented.

All experimental testing was conducted in a full-scale heating, ventilation, and air-conditioning (HVAC) laboratory using a realistic load profile and actual outdoor air temperature conditions. Experimental testing began with an evacuation, recycle, and recharge of R-22 from both circuits of the chiller. The charge tests included holding the refrigerant charge in circuit #2 constant at the manufacturer's recommended level. The notation adopted for the manufacturer's recommended charge or nominal charge level was 0% charge. Circuit #1's refrigerant charge was varied from -60% to +15% of nominal charge in 5% increments.

Units: Dual


File Size : 1 file , 370 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-7674
Published : 1998

History


Related products


Best-Selling Products

CAN/CSA-ISO/TS 11137-4:21
Published Date: 05/01/2021
Sterilization of health care products - Radiation - Part 4: Guidance on process control (Adopted ISO technical specification 11137-4:2020, first edition, 2020-06)
$72
CAN/CSA-ISO/TS 11139:18
Published Date: 06/01/2018
Sterilization of health care products - Vocabulary (Adopted ISO/TS 11139:2006, second edition, 2006-01-15)
$32.7
CAN/CSA-ISO/TS 14048-03 (R2021)
Published Date: 03/14/2003
Environmental Management - Life Cycle Assessment - Data Documentation Format (Adopted ISO/TS 14048:2002, first edition, 2002-04-01)
$50.4
CAN/CSA-ISO/TS 14798-07
Published Date: 03/01/2007
Lifts (Elevators), Escalators and Moving Walks - Risk Assessment and Reduction Methodology
$51.3
CAN/CSA-ISO/TS 16058-05
Published Date: 02/01/2005
Health Informatics - Interoperability of Telelearning Systems (Adopted ISO/TS 16058:2004, first edition, 2004-07-01)
CAN/CSA-ISO/TS 16775:17
Published Date: 10/01/2017
Packaging for terminally sterilized medical devices - Guidance on the application of ISO 11607-1 and ISO 11607-2 (Adopted ISO technical specification 16775:2014, first edition, 2014-05-15)
$68.7