This paper presents a study involving the operation of a 70-ton helical rotary, dual-circuit, air-cooled chiller while three independent variables are experimentally altered. The independent variables included in the study are refrigerant charge level within the chiller plant, outdoor air temperature, and percentage nominal chiller load. This paper examines the effects of the three independent variables on superheat and subcooling temperatures, chiller kW per ton, chilled water set-point temperature control, and compressor suction and discharge pressures. After analyzing the significance of refrigerant charge, outdoor air temperature, and percentage nominal chiller load on the operation of a chiller plant in an actual building, the consequences of refrigerant undercharge or overcharge are fully investigated and documented.

All experimental testing was conducted in a full-scale heating, ventilation, and air-conditioning (HVAC) laboratory using a realistic load profile and actual outdoor air temperature conditions. Experimental testing began with an evacuation, recycle, and recharge of R-22 from both circuits of the chiller. The charge tests included holding the refrigerant charge in circuit #2 constant at the manufacturer's recommended level. The notation adopted for the manufacturer's recommended charge or nominal charge level was 0% charge. Circuit #1's refrigerant charge was varied from -60% to +15% of nominal charge in 5% increments.

Units: Dual


File Size : 1 file , 370 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-7674
Published : 1998

History


Related products


Best-Selling Products

12051 CSMSB
Published Date: 01/01/2007
Chemical Safety Manual for Small Businesses
12051 ETHWM II
Published Date: 03/01/1998
Emerging Technologies in Hazardous Waste Management II
12051 FPI II
Published Date: 04/01/1998
Food and Packaging Interactions II
12051 GLPS
Published Date: 03/01/1998
Good Laboratory Practice Standards
12051 GRSD
Published Date: 11/01/1998
Groundwater Residue Sampling Design