4249 (RP-696) -- Evaluation of Service Hot Water Distribution System Losses in Residential and Commercial Installations: Part 1 - Field / Laboratory Experiments and Simulation Model PDF

4249 (RP-696) -- Evaluation of Service Hot Water Distribution System Losses in Residential and Commercial Installations: Part 1 - Field / Laboratory Experiments and Simulation Model PDF

Name:
4249 (RP-696) -- Evaluation of Service Hot Water Distribution System Losses in Residential and Commercial Installations: Part 1 - Field / Laboratory Experiments and Simulation Model PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Laboratory and field experiments were performed to provide data on heat losses from hot water piping systems. The objective of the research (ASHRAE Research Project 696) was to perform field experiments to determine heat loss in various piping systems. The piping systems, though, did not necessarily define the heat loss so as to be applicable to other systems of piping. Therefore, a numerical model was developed to simulate the heat loss, which is a more general and useful approach than field experiments. The laboratory and field experimental results were used, in part, as a comparison to the simulation results of a numerical model of heat loss (or gain) to water distribution piping systems. Experiments included the cases of noninsulated and insulated tubing over a range of flow rates and inlet water and ambient temperatures. Data obtained for both the residential and commercial installation field experiments consisted of water flow rates and water inlet and outlet temperatures. Analyses of the laboratory and field data are included in this paper along with an estimate of experimental error and uncertainty. The numerical model developed for estimating the heat loss (or heat gain) from insulated or noninsulated hot water pipes is discussed. The model calculates the two-dimensional temperature distribution in the water, pipe walls, and any insulation as a function of time and is capable of modeling steady flow or no flow (standby) conditions. The steady flow condition can be specified over a relatively short time span so that almost any draw schedule can be modeled. With the ability to model a range of parameters, the model can be used for comparative studies, such as establishing the heat loss differences between insulated and noninsulated piping, and for a companion paper.

Units: Dual


File Size : 1 file , 350 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-7535
Published : 1999

History


Related products


Best-Selling Products

CAN/CSA-ISO/IEC ISP 10608-1-99 (R2003)
Published Date: 02/22/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 1: General Overview and Subnetwork- Independent Requirements (Adopted ISO/IEC 10608-1:1992, first edition)
$21.9
CAN/CSA-ISO/IEC ISP 10608-12-99 (2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 12: MAC Sublayer and Physical Layer Dependent Requirements for a CSMA/CD LAN Subnetwork (Adopted ISO/IEC ISP 10608-12:1996)
$15.9
CAN/CSA-ISO/IEC ISP 10608-13-01
Published Date: 03/12/2001
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless-Mode Network Service - Part 13: MAC Sublayer and Physical Layer Dependent Requirements for a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-13:1994, first edition, 1994-0
$15.9
CAN/CSA-ISO/IEC ISP 10608-14-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 14: MAC, PHY and PMD Sublayer Dependent and Station Management Requirements Over an FDDI LAN Subnetwork (Adopted ISO/IEC ISP 10608-14:1995)
$27
CAN/CSA-ISO/IEC ISP 10608-2-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 2: TA51 Profile Including Subnetwork Dependent Requirements for CSMA/CD Local Area Networks (LANs) (Adopted ISO/IEC ISP 10608-2:1992)
$15.9
CAN/CSA-ISO/IEC ISP 10608-4-99 (R2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 4: Definition of Profile TA53, Operation Over a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-4:1994, first edition)
$14.1