4276 -- The Impact of Demand-Controlled and Economizer Ventilation trategies on Energy Use in Buildings PDF

4276 -- The Impact of Demand-Controlled and Economizer Ventilation trategies on Energy Use in Buildings PDF

Name:
4276 -- The Impact of Demand-Controlled and Economizer Ventilation trategies on Energy Use in Buildings PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The overall objective of this work was to evaluate typical energy requirements associated with alternative ventilation control strategies for constant-air-volume (CAV) systems in commercial buildings. The strategies included different combinations of economizer and demand-controlled ventilation, and energy analyses were performed for four typical building types, eight alternative ventilation systems, and twenty U.S. climates. Only single-zone buildings were considered so that simultaneous heating and cooling did not exist. The energy savings associated with economizer and demand-controlled ventilation strategies were found to be very significant for both heating and cooling. In general, the greatest savings in electrical usage for cooling with the addition of demand-controlled ventilation occur in situations where the opportunities for economizer cooling are less. This is true for warm and humid climates and for buildings that have relatively low internal gains (i.e., low occupant densities). As much as 20% savings in electrical energy for cooling were possible with demand-controlled ventilation. The savings in heating energy associated with demand-controlled ventilation were generally much larger but were strongly dependent upon the building type and occupancy schedule. Significantly greater savings were found for buildings with highly variable occupancy schedules and large internal gains (i.e., restaurants) as compared with office buildings. In some cases, the primary heating energy was virtually eliminated by demandcontrolled ventilation as compared with fixed ventilation rates. For both heating and cooling, the savings associated with demand-controlled ventilation are dependent on the fixed minimum ventilation rate of the base case at design conditions.

Units: Dual


File Size : 1 file , 3.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-7394
Published : 1999

History


Related products


Best-Selling Products

ARMY 03101
Published Date: 12/01/1992
FORMWORK FOR CONCRETE
$9.6
ARMY ADS-37A-PRF
Published Date: 05/28/1996
ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3) PERFORMANCE AND VERIFICATION REQUIREMENTS
$14.7
ARMY AMC P 715-17
Published Date: 03/15/1994
GUIDE FOR THE PREPARATION AND USE OF PERFORMANCE SPECIFICATIONS
$23.4
ARMY AR 1-100
Published Date: 07/27/2015
The Army Gift Program
$11.7
ARMY AR 1-15
Published Date: 01/31/2017
Civilian Aides to the Secretary of the Army
$10.2
ARMY AR 1-1
Published Date: 05/23/2016
Planning, Programming, Budgeting, and Execution
$14.1