4460 (RP-1077) -- Parametric Study of Charging Inlet Diffuser Performance in Stratified Chilled Water Storage Tanks with Radial Diffusers: Part 2—Dimensional Analysis, Parametric Simulations and Simplified Model Development PDF

4460 (RP-1077) -- Parametric Study of Charging Inlet Diffuser Performance in Stratified Chilled Water Storage Tanks with Radial Diffusers: Part 2—Dimensional Analysis, Parametric Simulations and Simplified Model Development PDF

Name:
4460 (RP-1077) -- Parametric Study of Charging Inlet Diffuser Performance in Stratified Chilled Water Storage Tanks with Radial Diffusers: Part 2—Dimensional Analysis, Parametric Simulations and Simplified Model Development PDF

Published Date:
2000

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A parametric study of the thermal performance during charging of a full-scale radial inlet diffuser in a cylindrical stratified chilled water storage tank was performed by applying factorial experimental theory to the results of simulations performed with a validated computational fluid dynamics (CFD) model. Part 1 describes the development and validation of the CFD model. Part 2 summarizes the results of the parametric study. Dimensional storage tank and inlet diffuser parameters having the potential to influence inlet thermal performance were identified, then formed into dimensionless groups using Buckingham Pi analysis. These included the inlet Richardson number (Ri), inlet Reynolds number (Rei), ratio of diffuser radius to tank radius (RD/Rw) and ratio of diffuser radius to diffuser inlet height (RD/hi). Thermal performance was measured in terms of thermocline thickness and equivalent lost tank height. Sixteen simulations comprising a full 2k factorial experiment were completed and analyzed. Parameter ranges considered were as follows: Ri from 1.0 to 11.1, Rei from 1,000 to 12,000, RD/Rw from 0.2 to 0.4 and RD/hi from 5 to 10. Within these ranges, Ri, RD/Rw and RD/hi were found to be of first-order significance while Rei was not. Regression models of thermal performance metrics as functions of Ri, RD/Rw and RD/hi that are sufficiently simple to be useful for design were developed. These models agreed well with CFD simulations from which they were derived and with field data.

Reprinted from the International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research, Vol. 7, No. 1, January 2001, pp. 51-65.

Units: Dual


File Size : 1 file , 320 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 18
Product Code(s) : D-7085
Published : 2000

History


Related products


Best-Selling Products

NS-EN ISO/ASTM 52900:2017
Published Date: 05/01/2017
Additive manufacturing - General principles - Terminology (ISO/ASTM 52900:2015)
NS-EN ISO/ASTM 52900:2021
Published Date: 12/16/2021
Additive manufacturing - General principles - Fundamentals and vocabulary (ISO/ASTM 52900:2021)
NS-EN ISO/ASTM 52901:2018
Published Date: 01/01/2019
Additive manufacturing - General principles - Requirements for purchased AM parts (ISO/ASTM 52901:2017)
NS-EN ISO/ASTM 52902:2019
Published Date: 12/01/2019
Additive manufacturing - Test artifacts - Geometric capability assessment of additive manufacturing systems (ISO/ASTM 52902:2019)
NS-EN ISO/ASTM 52903-1:2021
Published Date: 03/25/2021
Additive manufacturing - Material extrusion-based additive manufacturing of plastic materials - Part 1: Feedstock materials (ISO/ASTM 52903-1:2020)
NS-EN ISO/ASTM 52903-2:2020
Published Date: 11/16/2020
Additive manufacturing — Material extrusion based additive manufacturing of plastic materials — Part 2: Process equipment (ISO/ASTM 52903-2:2020)