This paper describes the performance of a refrigeration system when applied to a multizone industrial application driven by a common compressor. The limitations of current on/off type control using solenoid valves for such applications are outlined and methods of achieving more accurate temperature control are considered. As a result, electronic pressure regulating valves were selected and introduced to replace on/off type solenoids in a multizone refrigeration system consisting of three compartments, and their performance is compared against that obtained using solenoid valves for a series of temperature pull-down (cooling) tests. This paper describes the system hardware, the control algorithms used for controlling the electronic pressure regulating valves, and presents test results from both the electronic pressure regulating valves and solenoid activated control systems for three different test conditions. Overall, the electronic pressure regulating valves produced improved performance, indicating the following average results over the three zones: (1) 40% faster temperature pull-down to the setpoint, (2) 80% better setpoint temperature control, and (3) reduced temperature control problems arising from sudden changes in control valves in the status of neighboring zones.

Units: SI


File Size : 1 file , 630 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-8840
Published : 2002

History


Related products


Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
$12.9
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
$5.4
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
$23.7
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
$18.9
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
$22.2
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
$22.2