4634 -- Measured Performance of Conventional and High-Velocity Distribution Systems in Attic and Space Locations PDF

4634 -- Measured Performance of Conventional and High-Velocity Distribution Systems in Attic and Space Locations PDF

Name:
4634 -- Measured Performance of Conventional and High-Velocity Distribution Systems in Attic and Space Locations PDF

Published Date:
2003

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Residential distribution systems are inherently inefficient at delivering heated or cooled air to the conditioned space as the result of poor design and installation practices. Examples of some of the more common problems include heat loss/gain in unconditioned spaces and leakage through supply and return ducts. These defects can result in significantly increased energy consumption, poor thermal comfort, and high peak electricity demand. Efforts to improve distribution systems could result in substantial nationwide energy savings since more than fifty percent of existing homes have ducted systems. In an attempt to quantify the potential energy savings resulting from the elimination of duct losses, a field test was conducted to compare the energy consumption of an attic-ducted system to a no-loss duct system for two types of forced-air distribution systems: conventional and high-velocity. The no-loss system was achieved by locating the entire duct system and air handler in the conditioned space. The results were compared to predicted energy savings using ASHRAE Standard 152P as a means of validating the procedures used for determining distribution efficiency. The results from the tests indicate that, for the conventional system, placing the ducts in the conditioned space resulted in a measured energy savings of 31% (heating) and 36% (cooling). The predicted savings using ASHRAE Standard 152P were 33% for heating and 15% for cooling. For the high-velocity system, the measured energy savings were 46% (heating) and 35% (cooling). These compare to predicted savings of 51% for heating and 26% for cooling using the standard. Thus, for both types of distribution systems, the standard is a good predictor of heating energy savings but tends to underestimate the cooling energy savings. Additional tests were performed to determine the effects of locating the air handler in the conditioned space. The results of this series of tests indicate measured energy savings of 10% (conventional) and 9% (high-velocity) for heating, whereas Standard 152P predicts savings of 3% (conventional) and 8% (high-velocity). In this instance, the Standard 152P estimate is reasonable for the high-velocity system and low for the conventional system. For cooling, the measured savings were 11% for the high-velocity system compared to 8% as predicted by Standard 152P. Air handler location tests for the conventional system during the cooling season were inconclusive due to errors in the data.

Units: Dual


File Size : 1 file , 2.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 7
Product Code(s) : D-20902
Published : 2003

History


Related products


Best-Selling Products

AS/NZS 10002:2014
Published Date: 10/29/2014
Guidelines for complaint management in organizations
$31.68
AS/NZS 1015:2011
Published Date: 10/07/2011
Records management - Physical storage
$21.582
AS/NZS 1020:1995
Published Date: 03/05/1995
The control of undesirable static electricity
$36.63
AS/NZS 1020:2023
Published Date: 06/02/2023
The control of static electricity in non-hazardous areas
$23.166
AS/NZS 1026:2004
Published Date: 04/29/2004
Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV
$30.492
AS/NZS 1044:1992
Published Date: 08/17/1992
Limits and methods of measurement of radio interference characteristics of household electrical appliances, portable tools and similar electrical apparatus
$33.264