4653 (RP-1193) -- Pressure Loss Data for PVC Pipe Elbows, Reducers, and Expansions PDF

4653 (RP-1193) -- Pressure Loss Data for PVC Pipe Elbows, Reducers, and Expansions PDF

Name:
4653 (RP-1193) -- Pressure Loss Data for PVC Pipe Elbows, Reducers, and Expansions PDF

Published Date:
2003

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Pressure loss coefficients (K) were determined for only Schedule 80 PVC 90 degree elbows, reducers, and expansions. Injection molded PVC elbows were tested in the sizes of 2, 4, 6, and 8 in. (5.08, 10.16, 15.25, and 20.32 cm). Additional fabricated PVC elbows were tested in the 8 in. size (20.32 cm). Injection-molded PVC reducers and expansions were tested in the sizes of 6 by 4 in. (15.25 by 10.16 cm) and 8 by 6 in. (20.32 by 15.25 cm). The PVC reducers and expansions were both injection molded fittings and fittings fabricated from PVC bushing reducers and expansions. A total of 170 individual elbow, reducer, and expansion fittings from seven different vendors or manufacturers were tested in the ASHRAE project to determine pressure loss coefficients (K) of PVC fittings. The total number of individual test runs conducted for this study was 1,800, which were made in 13 different test setups. The scatter or variation in loss coefficients (K) between the different designs of the vendors was also evaluated in this study. Each test fitting was examined at a specified range of pipe velocities to determine the mean and variation of loss coefficients (K). All of the tests were performed with Schedule 80 PVC pipe and PVC fittings.

Units: Dual


File Size : 1 file , 2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 22
Product Code(s) : D-20933
Published : 2003

History


Related products


Best-Selling Products

PDA PTC PUPSIT 1
Published Date: 02/01/2020
Points to Consider for Risks Associated with Sterilizing Grade Filters and Sterilizing Filtration
$97.5
PDA PTC PUPSIT 2
Published Date: 03/01/2020
Points to Consider for Implementation of Pre-Use Post-Sterilization Integrity Testing (PUPSIT)
$97.5
PDA TR 13-2
Published Date: 11/01/2020
Technical Report No. 13-2 Fundamentals of an Environmental Monitoring Program Annex 1: Environmental Monitoring of Facilities Manufacturing Low Bioburden Products
$97.5
PDA TR 13
Published Date: 06/01/2014
Technical Report 13 Revised, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 13
Published Date: 04/22/2022
Technical Report 13 Revised 2022, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 14
Published Date: 09/01/2008
PDA Technical Report No. 14 (TR 14) Validation of Column-Based Chromatography Processes for the Purification of Proteins
$97.5