4683 – Impact of Modeling Accuracy on Predictive Optimal Control of Active and Passive Building Thermal Storage Inventory PDF

4683 – Impact of Modeling Accuracy on Predictive Optimal Control of Active and Passive Building Thermal Storage Inventory PDF

Name:
4683 – Impact of Modeling Accuracy on Predictive Optimal Control of Active and Passive Building Thermal Storage Inventory PDF

Published Date:
2003

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper evaluates the impact of modeling accuracy on the model-based closed-loop predictive optimal control of both passive building thermal capacitance and active thermal energy storage (TES) systems to minimize utility cost. The following guidelines have been derived: for an internal heat gain-dominated commercial building, the deviation of building geometry and zoning from the reference building only marginally affects the optimal control strategy; reasonable simplifications are acceptable without loss of cost savings potential. Building construction characteristics determine the building passive thermal storage capacity. Zone temperature setpoints are affected more than TES operation by this construction mismatch, and a loss of cost savings potential is found in some cases. It is advisable to make sure the construction material is well modeled. Zone temperature setpoint profiles and TES performance are strongly affected by mismatches in internal heat gains, especially when they are underestimated. Since they are a key factor determining the building cooling load, efforts should be invested to keep the internal gain mismatch as small as possible. Efficiencies of the building energy systems have no direct impact on building cooling load, but they affect both zone temperature setpoints and active TES operation because of the coupling of the base chiller and the TES chiller. Relative efficiencies of the base and TES chillers will determine the balance of operation of the two chillers. Mismatch in this category may be significant. To avoid critical modeling mismatch, system identification techniques may be useful in improving the modeling process.

Units: SI


File Size : 1 file , 1.9 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-21894
Published : 2003

History


Related products


Best-Selling Products

NBBI NB23-2004
Published Date: 01/01/2005
National Board Inspection Code - NBIC, 2004 Edition
NBBI NB23-2007 Part 2
Published Date: 12/31/2007
National Board Inspection Code - NBIC, 2007 Edition - Part 2 - Inspection
NBBI NB23-2011 Part 1
Published Date: 2011
National Board Inspection Code - NBIC, 2011 Edition - Part 1 - Installation
NBBI NB23-2015
Published Date: 2015
National Board Inspection Code - NBIC, 2015 Edition (Three Volumes)
NBBI NB23-2019 Part 1
Published Date: 2019
National Board Inspection Code - NBIC, 2019 Edition - Part 1 - Installation
NBBI NB23-2019 Part 2
Published Date: 2019
National Board Inspection Code - NBIC, 2019 Edition - Part 2 - Inspection