4715 (RP-1042) - Double-Walled Heat Exchanger Risk Analysis for Group B1 and Group B2 Refrigerants PDF

4715 (RP-1042) - Double-Walled Heat Exchanger Risk Analysis for Group B1 and Group B2 Refrigerants PDF

Name:
4715 (RP-1042) - Double-Walled Heat Exchanger Risk Analysis for Group B1 and Group B2 Refrigerants PDF

Published Date:
2004

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

In compliance with ANSI/ASHRAE Standard 15-2001, Safety Standard for Refrigeration Systems, a large quantity of Group B1 or Group B2 refrigerant cannot enter the occupied space of a building. Instead, a secondary fluid must be used to circulate through the refrigeration system’s components located within the occupied space. In typical systems, a single-walled liquid-to-liquid heat exchanger is used outdoors with an air coil in the occupied space. In this study, a double-walled heat exchanger is considered to replace these two components, where the double-walled configuration prevents leaking refrigerant from entering the occupied space of a building. Consequently, the double-walled heat exchanger located in the occupied space serves as a direct expansion coil. While any Group B1 or Group B2 refrigerant may be considered, ammonia, which is a Group B2 refrigerant, became the focus of this study due to the availability of commercial absorption units.

Four refrigeration system concepts are developed. One system—the reference system—represents current system design, incorporating a single-walled heat exchanger and an air coil. Three other proposed systems are also described, each containing a double-walled heat exchanger. Twelve design criteria accompany these proposed systems, which must meet the safety requirements provided.

From reliability data gathered and the calculations made, the three proposed conceptual systems are found to be at least as, if not more, reliable than the reference conceptual system in two comparisons. Considering the systems in their entirety, the reference system has a reliability value of 0.639, and the three proposed conceptual systems have reliability values of 0.654 or greater. Similar results in comparison are attained when considering the portion of the system from which refrigerant would escape to the occupied space.

Since the proposed system reliabilities are equivalent to the reference system using a secondary fluid, the proposed systems are determined to be no more of a risk to safety than current systems. Thus, the application of the double-walled heat exchanger, which permits the refrigerant to enter the occupied space, appears acceptable on the basis of this risk analysis.

Units: SI


File Size : 1 file , 240 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-23214
Published : 2004

History


Related products


Best-Selling Products

BOCA 301-99
Published Date: 01/01/1999
1999 National Building Code - SOFTCOVER
BOCA 302-99
Published Date: 01/01/1999
1999 National Building Code - LOOSELEAF
BOCA 303-93
Published Date: 01/01/1993
1993 National Plumbing Code
$22.8
BOCA 307-99
Published Date: 01/01/1999
1999 National Fire Prevention Code - SOFTCOVER
$175.5
BOCA 345-2000
Published Date: 01/01/2000
2000 International Mechanical Code - SOFTCOVER
$24.6
BOCA 345-98
Published Date: 09/01/1998
1998 International Mechanical Code - SOFTCOVER
$24.6