4716 - Effect of Boundary Conditions on the Prediction of Temperature Distribution for Curtain Walls PDF

4716 - Effect of Boundary Conditions on the Prediction of Temperature Distribution for Curtain Walls PDF

Name:
4716 - Effect of Boundary Conditions on the Prediction of Temperature Distribution for Curtain Walls PDF

Published Date:
2004

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Previous studies have indicated that the application of variable local film coefficients can improve the accuracy of temperature predictions for fenestration systems using two-dimensional programs, such as FRAME and THERM. However, the discrepancy between simulation and test results for metal-framed windows is relatively large, e.g., a typical 5oC (9oF) discrepancy may exist in the frame area. One of the possible reasons was believed to be the lack of test data that were reported with accurate measurement locations and test conditions. In a comprehensive experimental study carried out by the authors on the overall performance of metal curtain walls, extensive temperature measurements enabled more accurate comparison between simulations and tests. Several sets of boundary conditions were assigned to the sill sections of two different curtain wall systems in the FRAME simulations. The variation of local film coefficients along the room-side frame surface was considered.

The comparison between simulation results and test data indicates that the proper application of more realistic boundary conditions can greatly improve the accuracy of computer simulations in predicting the temperature distributions and thus the condensation resistance performance for fenestration systems. The application of local film coefficients to the frame surface reduces significantly the discrepancy between simulation and test results to within +-0.5°C (+-0.9°F) for the standard curtain wall system and to within +2°C (+3.6°F) for the highly insulated system. These improvements confirm the importance of assigning more realistic boundary conditions to the frame area for metal-framed fenestration systems. The results also suggest that the convection motion in the glazing cavity should be considered in order to obtain more accurate results for edge-of-glass in simulations.

Units: Dual


File Size : 1 file , 400 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-23215
Published : 2004

History


Related products


Best-Selling Products

IEC/PAS 60027-6 Ed. 1.0 en:2004
Published Date: 09/20/2004
Letter symbols to be used in electrical technology - Control technology
$12.6
IEC/PAS 60050-732 Ed. 1.0 b:2007
Published Date: 06/06/2007
International Electrotechnical Vocabulary - Part 732: Computer network technology
$61.2
IEC/PAS 60092-510 Ed. 1.0 en:2009
Published Date: 04/29/2009
Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems
$89.7
IEC/PAS 60099-7 Ed. 1.0 en:2004
Published Date: 04/27/2004
Surge arresters - Part 7: Glossary of terms and definitions from IEC publications 60099-1, 60099-4, 60099-6, 61643-1, 61643-12, 61643-21, 61643-311, 61643-321, 61643-331 and 61643-341
$95.1
IEC/PAS 60191-6-18 Ed. 1.0 en:2008
Published Date: 01/22/2008
Mechanical standardization of semiconductor devices - Part 6-18: General rules for the preparation of outline drawings of surface mounted semiconductor device packages - Design guide for ball grid array (BGA)
$29.1
IEC/PAS 60191-6-19 Ed. 1.0 en:2008
Published Date: 01/22/2008
Mechanical standardization of semiconductor devices - Part 6-19: Measurement methods of package warpage at elevated temperature and the maximum permissible warpage
$32.1