4751 - Field Observations of Room Air Distribution Performance in Two Rooms of a Cold-Climate Home PDF

4751 - Field Observations of Room Air Distribution Performance in Two Rooms of a Cold-Climate Home PDF

Name:
4751 - Field Observations of Room Air Distribution Performance in Two Rooms of a Cold-Climate Home PDF

Published Date:
2005

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The objective of this investigation was to evaluate the field performance of room air distribution in two rooms of a highperformance (low heating and cooling load) home. The two rooms had similar exterior exposures but had different supply register locations (high sidewall and floor). The impact of normal equipment cycling on the room air distribution performance was also investigated. The performance was evaluated based on room air temperature measurements and the requirements of ASHRAE Standard 55 (ASHRAE 1992). Measurements were made in a test home in Pittsburgh, Pennsylvania (cold climate), during both heating and cooling periods, after the air distribution system had been balanced. The room with the high sidewall register (bedroom) had approximately 75% of the design airflow based on load calculations, and the room with the floor register (dining room) had approximately 100% of the design airflow. A conclusion of the study, based on stratification and temperature cycling performance, is that high sidewall supply with a nonspreading register at an interior wall is effective for both heating and cooling operation in a cold climate. Another conclusion from this investigation is that floor supply with a spreading register at an exterior wall provides marginal heating operation in a high-performance home, as indicated by higher vertical temperature stratification and unacceptable temperature cycling. All of the conclusions from this investigation are limited to the conditions of the room air distribution methods studied and are worthy of further investigation. Additional research is recommended to investigate the effect of supply air temperature, register throw, alternate equipment control, and outlet location on room air distribution performance in residential applications.

Units: Dual


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-25638
Published : 2005

History


Related products


Best-Selling Products

IETF 8254-2
Published Date: 07/01/2016
Papiers et cartons - Mesurage du brillant spéculaire - Partie 2: Brillant à 75° avec un faisceau parallèle, méthode DIN
$24.3
IETF FAA AC 43-10
Published Date: 02/01/1983
MECHANICAL WORK PERFORMED ON U.S. AND CANADIAN REGISTERED AIRCRAFT
IETF RFC 1000
Published Date: 08/01/1987
The Request for Comments Reference Guide
$21
IETF RFC 1002
Published Date: 03/01/1987
PROTOCOL STANDARD FOR A NetBIOS SERVICE ON A TCP/UDP TRANSPORT: DETAILED SPECIFICATIONS
$18.3
IETF RFC 1014
Published Date: 06/01/1987
XDR: EXTERNAL DATA REPRESENTATION STANDARD
IETF RFC 1042
Published Date: 02/01/1988
A Standard for the Transmission of IP Datagrams over IEEE 802 Networks
$10.2