4815 (RP-1171) - Sources of Uncertainty in the Calculation of Design Weather Conditions PDF

4815 (RP-1171) - Sources of Uncertainty in the Calculation of Design Weather Conditions PDF

Name:
4815 (RP-1171) - Sources of Uncertainty in the Calculation of Design Weather Conditions PDF

Published Date:
2005

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

In this research we examine the uncertainty associated with the design weather conditions (DWC) as found in the ASHRAE Handbook—Fundamentals. The work is organized around three main objectives. The first objective is to determine the error associated with typical data limitations, such as nonhomogeneous data, incomplete data, and insufficient data. The second objective is to develop methods to estimate the percentiles of hourly dry-bulb temperature from daily data and to estimate humidity-related design weather conditions when no humidity data are available. The final objective is to determine the frequency and duration of episodes during which the ASHRAE DWC are met or exceeded. We find for dry-bulbrelated DWC that various data limitations are generally minimal (uncertainty less than 1°C) for a station if at least ten years of data are available. For DWC involving psychrometric variables, the probable error was shown to vary with measuring system and ambient conditions. Methods developed for estimating hourly DWC from daily values proved reliable (mean absolute error less than 1°C). The estimation of wet-bulb DWC when only dry-bulb temperatures are available is challenging, but a useful method was developed (mean absolute error near 1°C). Episodic behavior of the frequency/duration of DWC was examined and in some sites is consistent with known trends in urban warming. There was no evidence of episodic behavior of DWC except for areas undergoing rapid urbanization.


File Size : 1 file , 650 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-27020
Published : 2005

History


Related products


Best-Selling Products

UNE-CLC/TR 50373:2006 IN
Published Date: 06/07/2006
Wind turbines - Electromagnetic compatibility
UNE-CLC/TR 50453:2008 IN
Published Date: 11/26/2008
Evaluation of electromagnetic fields around power transformers
UNE-CLC/TR 50462:2009
Published Date: 10/14/2009
Rules for the determination of uncertainties in the measurement of the losses on power transformer and reactors
UNE-CLC/TR 50488:2007 IN
Published Date: 07/18/2007
Railway applications - Safety measures for the personnel working on or near overhead contact lines