4833 - Impacts of Manufacturing Tolerances on the Effectiveness-Ntu Method for Regenerative Exchanger Design PDF

4833 - Impacts of Manufacturing Tolerances on the Effectiveness-Ntu Method for Regenerative Exchanger Design PDF

Name:
4833 - Impacts of Manufacturing Tolerances on the Effectiveness-Ntu Method for Regenerative Exchanger Design PDF

Published Date:
2006

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

In the design of regenerative exchangers, the number of transfer units, Ntu, is directly proportional to the surface area and inversely proportional to the mass flow rate; it is usually regarded as constant for applications with specified operating conditions. The effectiveness–Ntu method of design is the preferable design method in HVAC applications because the outlet flow properties are readily predicted once the inlet properties are known. This study is intended to show that the effective Ntu decreases when manufacturing tolerances in the flow channels are considered for regenerative exchangers. The analysis shows that the effective Ntu decreases when tolerances in the manufacturing process cause a significant random variation in flow channel sizes, which is characterized by the ratio of flow channel standard deviation to mean hydraulic diameter (s/D0). Graphical results are presented to show quantitatively how manufacturing tolerances decrease the effective value of Ntu for regenerative exchangers. Four rotary regenerative exchangers measured show that the ratio of Ntu effective value and design value, Ntu/Ntu0, ranges between 0.57 and 0.94 for typical operating conditions.

Units: SI


File Size : 1 file , 4.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-28006
Published : 2006

History


Related products


Best-Selling Products

ICEA P-117-734-2016
Published Date: 02/23/2016
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$90
ICEA P-117-734-2022
Published Date: 07/06/2022
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$96
ICEA P-123-739-2018
Published Date: 01/18/2018
GUIDE TO ESTABLISH ELECTRICAL TEST METHODS FOR NON-CONDUCTING JACKET MATERIALS FOR POWER CABLES RATED 5 TO 500 KV
$22.5
ICEA P-124-736-2021
Published Date: 06/03/2021
Code Words for 600 Volt Underground Distribution Cables
$13.5
ICEA P-127-737-2021
Published Date: 06/03/2021
Code Words for Overhead Aluminum Covered Conductors and 600 Volt Overhead Cables
$13.5
ICEA P-136-726-2024
Published Date: 2024
Guide for Pellet Inspection Systems for Unfilled Power Cable Insulation Compound
$29.1