A Simplified Personalized and Displacement Ventilation Model for Predicting Passive Contaminant Spread in Office Spaces PDF

A Simplified Personalized and Displacement Ventilation Model for Predicting Passive Contaminant Spread in Office Spaces PDF

Name:
A Simplified Personalized and Displacement Ventilation Model for Predicting Passive Contaminant Spread in Office Spaces PDF

Published Date:
2018

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
The purpose of this work is to develop a mathematical multi-layer, multi-plume model of passive contaminant spread for office spaces equipped with displacement ventilation (DV) coupled with a personalized ventilation system (PV). The model studies the transport of species and therefore predicts occupant risk of infection in typical office spaces. The particle concentrations in the thermal plumes and the surrounding air are separately evaluated in each air layer in the space. The PV is taken into account in the occupant breathing zone and affects the species’ concentration in the rising thermal plume. The temperatures and concentrations at each layer are computed by solving the energy and mass balance equations. On the other hand, the temperature and concentration at the breathing zone are calculated by discretizing the PV jet into vertical control volumes and performing energy and mass balance at each PV layer. The model is then validated experimentally in a climatic chamber equipped with a DV+PV system and a heated cylinder representing an occupant in a typical office space. Validation of the model is performed for a DV flow rate of 60 L/s (127.13 CFM) and a supply temperature of 19°C (66.2°F) along with a typical PV flow rate of 3.5 L/s (7.41 CFM) and supply temperature of 22°C (71.6°F). Good agreement is obtained between measured and predicted values by the model with maximum errors of 7.44% for temperature and 4.47% for concentration found in the macroclimate air.Key-words: personalized ventilation, displacement ventilation, mathematical model, indoor air quality
File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-ICEB18-C029
Published : 2018
Units of Measure : Dual

History


Related products


Best-Selling Products

UNE-CEN/TS 1099:2009 EX
Published Date: 06/24/2009
Plywood - Biological durability - Guidance for the assessment of plywood for use in different use classes
UNE-CEN/TS 12169:2009 EX
Published Date: 10/28/2009
Criteria for the assessment of conformity of a lot of sawn timber
UNE-CEN/TS 12200-2:2004
Published Date: 11/12/2004
Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Guidance for the assessment of conformity
UNE-CEN/TS 12201-7:2007 EX
Published Date: 05/23/2007
Plastics piping systems for water supply - Polyethylene (PE) - Part 7: Guidance for the assessment of conformity
UNE-CEN/TS 12390-9:2008 EX
Published Date: 05/07/2008
Testing hardened concrete - Part 9: Freeze-thaw resistance - Scaling
UNE-CEN/TS 13001-3-1:2006 EX
Published Date: 06/14/2006
Cranes - General design - Part 3-1: Limit states and proof of competence of steel structures