AC-02-10-1 -- Economic Assessment of Low Firing Temperature Absorption Chiller Systems PDF

AC-02-10-1 -- Economic Assessment of Low Firing Temperature Absorption Chiller Systems PDF

Name:
AC-02-10-1 -- Economic Assessment of Low Firing Temperature Absorption Chiller Systems PDF

Published Date:
2002

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The performance and economics of large (600 ton, 2110 kW) single-effect and half-effect absorption chiller systems fired with hot water were investigated. The single-effect system operates at nearly constant coefficient of performance (COP) of approximately 0.65, but capacity decreases precipitously as the temperature of the hot water entering the generator is lowered from the design value of 230°F (110°C). The half-effect cycle can maintain capacity with lower hot water firing temperatures, but it operates at significantly lower COP, which requires more energy input to the generator and heat rejection through the cooling tower, compared to the single-effect system. The purpose of this investigation was to compare the performance and economics of the single- and half-effect systems as a function of hot water firing temperatures. A detailed computer model was written for the single- and half-effect systems. The single-effect model was calibrated with data from a chiller manufacturer. The results indicate that the economics of the half-effect system become more favorable than those for the single-effect system for inlet hot water temperatures lower than approximately 200°F (93°C). However, at these operating conditions, the half-effect system is not economically competitive with electrically driven centrifugal chillers on a five-year life-cycle economic basis, even if the inlet hot water is available at no cost.

Units: Dual


File Size : 1 file , 380 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-7009
Published : 2002

History


Related products


Best-Selling Products

VG 95370-10
Published Date: 12/01/1983
Electromagnetic Compatibility; Electromagnetic Compatibility of & in Systems - Test Method for Interference Currents
VG 95374-1
Published Date: 11/01/1992
Electromagnetic Compatibility (EMC) including Electromagnetic Pulse (EMP) and Lightning Protection - Program and Procedures - Administrative Regulations