AC-02-15-1 -- Performance Analysis of U-Tube, Concentric Tube, and Standing Column Well Ground Heat Exchangers Using a System Simulation Approach PDF

AC-02-15-1 -- Performance Analysis of U-Tube, Concentric Tube, and Standing Column Well Ground Heat Exchangers Using a System Simulation Approach PDF

Name:
AC-02-15-1 -- Performance Analysis of U-Tube, Concentric Tube, and Standing Column Well Ground Heat Exchangers Using a System Simulation Approach PDF

Published Date:
2002

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The design length of ground heat exchangers for geother-mal heat pump systems is strongly dependent on the borehole thermal resistance. The borehole thermal resistance is defined by the thermal properties of the materials of construction and the arrangement of flow channels of the ground heat exchanger and strongly influences the performance of a geothermal heat pump system. Simulation studies are presented that examine and compare the thermal performance of some of the more common types of ground heat exchangers, such as single U-tube, double U-tube, concentric tube, and standing column well (with no groundwater bleed), using a mathematical description for the thermal resistance of ground heat exchangers. The system simulations are based on a short time step ground heat exchanger model and are conducted under an equivalent set of conditions considering a small office building. Results show that the single U-tube requires the greatest length of bore for the conditions simulated. Theoretical reductions in total bore length of approximately 22%, 33%, and 36% are seen for the double U-tube, the concentric tube, and the standing column well with no bleed, respectively. A comparative life-cycle cost analysis is also conducted considering a 20-year system operation.

Units: Dual

 


File Size : 1 file , 430 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-7023
Published : 2002

History


Related products


Best-Selling Products

Acceptance sampling pack
Published Date: 02/01/2001
$348.996
Accuracy and precision pack
Published Date: 02/01/2001
$205.74
Achieving ISO/IEC 20000 series promotional kit
Published Date: 03/31/2006
$89.154
Action on structures
Published Date: 07/30/2010
$1045.464
Aluminium and aluminium alloys pack
Published Date: 07/15/1999
$232.41