AC-75-06-2 -- Humidity Control and Energy Conservation PDF

AC-75-06-2 -- Humidity Control and Energy Conservation PDF

Name:
AC-75-06-2 -- Humidity Control and Energy Conservation PDF

Published Date:
1975

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The energy shortage has triggered many uncertainties in the present practices of system design and control within the building industry. One of these uncertainties is the effect of humidification on energy conservation. In the near past, it was accepted that there are benefits to maintain certain humidity levels. To assess whether humidification does conserve energy, it is necessary to consider simultaneously the following: heat transfer through the structure, infiltration, condition of outside air, moisture addition, and moisture sources in the controlled space. The results should be compared with the energy consumption of the same configuration but without humidification. Such an analysis should be dynamic and throughout the season.

A great deal of material was published on the effect of humidification on people comfort, and recently ASHRAE has adopted a new comfort standard (see Fig. 1). It is obvious that it is desirable to maintain in winter low humidity and low temperature in order to minimize energy consumption for heating and humidification. In summer, it is obvious that it is desirable to maintain the highest possible dry-bulb temperature and humidity in order to conserve energy that is required for cooling and dehumidification.

This paper is directed towards commercial and industrial buildings where the humidification and dehumidification are done in the air handling unit, rather than moisture addition in space itself. This paper will consider the many aspects of humidification and dehumidification and their effect on energy input into the system.

As is well known, a commercial building can be subdivided into an interior zone and an exterior zone. The exterior zone is equipped with systems to compensate the heat gain or loss through the envelope of the building including the internal loads. The interior zone is invariant to outdoor conditions and has to handle only the internal heat sources. In the commercial building, the air handling systems, in general, are divided into interior air handling systems and exterior air handling systems. The discussion from here on will, relate to such configuration.


File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 15
Product Code(s) : D-AC-75-06-2
Published : 1975

History


Related products


Best-Selling Products

ECMA 100
Published Date: 12/01/1988
Data Interchange on 90mm Flexible Disk Cartridges Using MFM Recording at 7 958 ftprad on 80 Tracks on Each Side-ISO Type 301, Second Edition
ECMA 102
Published Date: 07/01/1987
Rate Adaptation for the Support of Synchronous and Asynchronous Equipment Using the V. Series Type Interface on a PCSN, Second Edition
ECMA 106
Published Date: 12/01/1993
PTN - Signaling Protocol at the S Reference Point - Circuit Mode Basic Services (SSIG-BC), Third Edition
$5.4
ECMA 107
Published Date: 06/01/1995
Volume and File Structure of Disk Cartridges for Information Interchange, Second Edition
$5.4
ECMA 108
Published Date: 12/01/1996
Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment, Third Edition
$5.4
ECMA 109
Published Date: 12/01/1996
Declared Noise Emission Values of Information Technology and Telecommunications Equipment
$5.4