Active Humidity Control and Continuous Ventilation for Improved Air Quality in Schools PDF

Active Humidity Control and Continuous Ventilation for Improved Air Quality in Schools PDF

Name:
Active Humidity Control and Continuous Ventilation for Improved Air Quality in Schools PDF

Published Date:
2001

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A research project was undertaken, investigating the impact on school indoor air quality of active humidity control and continuous ventilation, with the objectives of (1) measuring the importance of humidity control and continuous ventilation on school indoor air quality, (2) developing baseline indoor air quality data for schools in hot and humid climates, (3) providing data and recommendations for HVAC designs for improving indoor air quality in schools, and (4) documenting the role of desiccant technologies to actively control humidity in schools. A literature review of school indoor air quality was the first task followed by a field investigation of the indoor air quality in ten noncomplaint Georgia schools in matched pairs of schools with conventional systems and schools with desiccant-cooling systems. Continuous monitors for carbon dioxide, temperature, and humidity were placed in one location in each school for approximately one year. In the same room with the continuous monitor, time-weighted volatile organic compound (VOC) samples were taken for approximately 30- day periods throughout the investigational period. Additionally on-site samples were collected at least four times during the year for VOCs, particles, bioaerosols, aldehydes and ketones, CO2 , carbon monoxide, temperature, humidity, and air change rate to more thoroughly assess the indoor air quality in the schools. Using discriminant analysis, statistically significance differences between the indoor air quality in the two groups of schools, those with the conventional HVAC systems versus those with the desiccant cooling systems, was found when looking at each sampling period. The groupings were adjusted for the times when the desiccant systems were not operating in individual schools. The Wilks' Lambda values ranged between 0.163 and 0.276, depending on the period, and r < 0.001. The importance of ventilation rates of at least 15 cfm/person were demonstrated by the CO2 and other contaminant levels in the schools. The CO2 and other contaminant levels in the schools also demonstrated the impact of poor maintenance practices and ventilation system design. This paper presents an overview of the ventilation and temperature findings.


Authors: Charlene W. Bayer, Ph.D., Robert J. Hendry, John C. Fischer, Sidney A. Crow, Ph.D.

Citation: Indoor Air Quality 2001 Moisture, Microbes, and Heath Effects: Indoor Air Quality and Moisture in Buildings Conference Papers

Keywords: November, California, 2001, IAQ


File Size : 1 file , 790 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8167
Published : 2001

History


Related products


Best-Selling Products

ASHRAE/AMCA 51-1999 Addendum a-2001
Published Date: 2001
Addendum a-2001 to Standard 51-1999 -- Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (AMCA Standard 210-99) (ANSI approved)
Free Download
ASHRAE/AMCA 51-1999
Published Date: 1999
Standard 51-1999 -- Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (AMCA Standard 210-99) (ANSI approved)
$21.6
ASHRAE/AMCA 51-2007
Published Date: 2008
Standard 51-2007 -- Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (ANSI/ASHRAE Approved) (ANSI/AMCA Standard 210-07)
$32.7