AL-2503 -- Control of Low Frequency Duct-Generated Noise in Building Air Distribution Systems PDF

AL-2503 -- Control of Low Frequency Duct-Generated Noise in Building Air Distribution Systems PDF

Name:
AL-2503 -- Control of Low Frequency Duct-Generated Noise in Building Air Distribution Systems PDF

Published Date:
1978

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

One of the primary sources of rumble originates in building air-handling systems ductwork. Poor duct system design often restts in the creation of excessively turbulent flow inside the ductwork. This turbulence excites low-frequency duct-related resonances, and results in noise radiation to adjoining occupied spaces. Because of its flexibility, rectangular ductwork is more apt to cause problems than is circular ductwork.

Once generated, sound energy in the 16, 31.5, 63, and J25 Hz octave bands is not readily attenuated by "add-ons" to the system. Often, attempts to attenuate this noise with fixes such as mufflers, duct lagging, etc., make the problem worse since these devices attenuate the high frequencies without significantly affecting tpe low frequency energy. The result is an even more unbalanced sound spectra with the low frequencies dominating and the resulting noise heard as rumble.

The resolution of most of these problems depends on the use of good design practice in sizing and specification of the building ductwork. Cerami, Shatalon and Bishop (1), (2) have provided reasonable design guidelines which, if followed, tend to minimize separated flow and the resulting duct rumble. ~dditional recommended practices are also suggested by Kingsbury and Sessler (3). However, these guidelines cannot always be followed due to limitations of available space in which to mount the air handler and associated ductwork. Often a designer must compromise and expand air in a shorter distance than recommended and place elbows very close to the fan cutoff. This paper discusses these factors and suggests design guidelines for duct design and the design of mechanical equipment rooms to minimize and/or contain noise from air distribution systems.


File Size : 1 file , 800 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-AL-2503
Published : 1978

History


Related products


Best-Selling Products

ISO/IEC/IEEE 12207-2:2020
Published Date: 08/01/2020
Systems and software engineering - Software life cycle processes - Part 2: Relation and mapping between ISO/IEC/IEEE 12207:2017 and ISO/IEC 12207:2008
$83.4
ISO/IEC/IEEE 14764:2022
Published Date: 08/01/2022
Software engineering - Software life cycle processes - Maintenance
$66.9
ISO/IEC/IEEE 15026-1:2019
Published Date: 08/01/2019
Systems and software engineering - Systems and software assurance - Part 1: Concepts and vocabulary
$58.2
ISO/IEC/IEEE 15026-2:2022
Published Date: 10/31/2022
Systems and software engineering - Systems and software assurance - Part 2: Assurance case
$49.8
ISO/IEC/IEEE 15026-3:2023
Published Date: 11/01/2023
Systems and software engineering - Systems and software assurance - Part 3: System integrity levels
$49.8
ISO/IEC/IEEE 15026-4:2021
Published Date: 08/01/2021
Systems and software engineering - Systems and software assurance - Part 4: Assurance in the life cycle
$66.9