AN-92-11-1 -- Precooling and Direct-Cooling Coils for Groundwater, Lake Water, and Water-Loop Heat Pump Systems PDF

AN-92-11-1 -- Precooling and Direct-Cooling Coils for Groundwater, Lake Water, and Water-Loop Heat Pump Systems PDF

Name:
AN-92-11-1 -- Precooling and Direct-Cooling Coils for Groundwater, Lake Water, and Water-Loop Heat Pump Systems PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Groundwater and deep lake water can potentially serve as a vast network of seasonal chilled thermal storage reservoirs. These reservoirs have been used as heat sinks and sources for water-to-air heat pumps and other types of chillers (Brown et al. 1988. Radkliffe and Schabel 1986. Kavanaugh 1987). On a more limited basis, these reservoirs have been directly used as a source of chilled water (Tomlinson and Kannburg 1990. Brett and Schaetzle 1984. Kavanaugh 1990). These studies have shown that precooling or total cooling of building return air with water can substantially reduce cooling energy use even in southern climates. A variety of schemes, both open and closed loops, can be incorporated to link reservoirs to traditional building air-and-water or all water equipment. Precooling and direct cooling can also be incorporated into water-loop heat pump systems that have a core cooling load during the heating season. Presents a general approach for sizing the direct-cooling and precooling water-to-air (hydronic) coils. Secondly, covers possible methods of integrating the coils with water-to-air heat pumps for both cooling and heating. Finally, presents a method of estimating the heat transfer in the piping between the reservoirs and the building (Kavanaugh 1991).

KEYWORDS: precooling, direct cooling, cooler batteries, heat pumps, water air heat pumps, heating, calculating, heat flow, pipes, lakes, water heat pumps, ground water, reservoirs, heat sinks, cold sources, seasonal heat storage, chillers, energy conservation, buildings, sizing, water air heat exchangers


File Size : 1 file , 750 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-18047
Published : 1992

History


Related products


Best-Selling Products

UNE-IEC/TR 60865-2:2006 IN
Published Date: 04/26/2006
Short-circuit currents - Calculation of effects - Part 2: Examples of calculation.
UNE-IEC/TR 60893-4:2005
Published Date: 02/09/2005
Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 4: Typical values
UNE-IEC/TR 60909-2:2010 IN
Published Date: 02/17/2010
Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations.
UNE-IEC/TR 61000-2-8:2006 IN
Published Date: 06/28/2006
Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results (IEC/TR 61000-2-8:2002)
UNE-IEC/TR 61000-3-6:2006 IN
Published Date: 07/19/2006
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 6: Assessment of emission limits for distorting loads in MV and HV power systems - Basic EMC publication (IEC/TR 61000-3-6:1996)
UNE-IEC/TR 61010-3:2006 IN
Published Date: 03/15/2006
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3: Protocol for the preparation of conformity verification reports for the IEC 61010 2nd edition series .