AT-01-15-3 -- Condensation and Icing in Gas Turbine Systems: Inlet Air Temperature and Humidity Limits PDF

AT-01-15-3 -- Condensation and Icing in Gas Turbine Systems: Inlet Air Temperature and Humidity Limits PDF

Name:
AT-01-15-3 -- Condensation and Icing in Gas Turbine Systems: Inlet Air Temperature and Humidity Limits PDF

Published Date:
2001

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The possibility of ice or condensation forming on the surfaces of the inlet bellmouth or inlet guide vanes of a gas turbine depends upon the entering (inlet) air temperature and relative humidity, along with the air pressure loss that occurs between the bellmouth inlet and the inlet guide vanes, just upstream of the first stage of the compressor. Based upon a known inlet to compressor or inlet guide vane pressure loss and a given inlet air temperature, an upper limiting inlet air relative humidity limit can be predicted to prevent icing or conden-sation in the bellmouth up to the compressor. The predicted limiting relative humidities reported here are based upon simulated turbine inlet surface temperatures from previous research using a recovery factor, which agreed well with some limited experimental non-icing condition data. The results shown in this study cover a range of turbine inlet air pressure losses up to 4 psi (27.6 kPa) and inlet air temperatures from 70ºF to 0ºF (21.1ºC to -17.8ºC). Previous research has shown that at 100% relative humidity, the ambient/cooled inlet air temperature is limited to between 35ºF and 40ºF (1.7ºC and 4.4ºC) to prevent condensation and possible ice formation on the inlet guide vanes. Both the previous research and this study predict that there is no limiting low inlet air temperature to prevent surface icing as long as the corresponding inlet air relative humidity is below a limiting value, though fog and ice crystals will probably form in the airstream.

Units: Dual


File Size : 1 file , 640 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 5
Product Code(s) : D-7193
Published : 2001

History


Related products


Best-Selling Products

ISO/HL7 10781:2015
Published Date: 08/01/2015
Health Informatics - HL7 Electronic Health Records-System Functional Model, Release 2 (EHR FM)
$71.1
ISO/HL7 16527:2016
Published Date: 08/01/2016
Health informatics - HL7 Personal Health Record System Functional Model, Release 1 (PHRS FM)
$71.1
ISO/HL7 21731:2014
Published Date: 08/01/2014
Health informatics - HL7 version 3 - Reference information model - Release 4
$66.9
ISO/HL7 27931:2009
Published Date: 08/01/2009
Data Exchange Standards - Health Level Seven Version 2.5 - An application protocol for electronic data exchange in healthcare environments
$83.4
ISO/HL7 27932:2009
Published Date: 08/01/2009
Data Exchange Standards - HL7 Clinical Document Architecture, Release 2
$83.4
ISO/HL7 27951:2009
Published Date: 08/01/2009
Health informatics - Common terminology services, release 1
$83.4