AT-19-008 -- Energy Performance, Comfort, and Lessons Learned from an Institutional Building Designed for Net Zero Energy PDF

AT-19-008 -- Energy Performance, Comfort, and Lessons Learned from an Institutional Building Designed for Net Zero Energy PDF

Name:
AT-19-008 -- Energy Performance, Comfort, and Lessons Learned from an Institutional Building Designed for Net Zero Energy PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
This paper examines the early performance of the VarennesLibrary, a building designed for net-zero annual energy balancein Varennes, near Montréal, Canada. It produces electricity froma 110.5 kWp building-integrated photovoltaic (BIPV) systemwhere heat is also recovered from a section of the array and usedto preheat the outdoor air intake. The building’s many architecturalandmechanicalfeatureswereintegrallydesignedtoachievethe net zero energy target over a five-year averaging period withseveral key decisions made at the early design stage. Theseinclude the shape, area,andorientation of the roof thatmaximizeselectricity productionfromtheBIPV(partBIPV/T[building-integratedphotovoltaic/thermal with heat recovery]) system and adesign layout that promotes daylight penetration and naturalventilation/freecoolingduringthecoolingseason.In the firstyearafter inauguration, an operational energy use intensity (EUI) of24.8 kBtu/ft2y (78.1 kWh/m2y) was achieved and has since beenreduced to 22.20 kBtu/ft2y (70.0 kWh/m2y). Considering renewablesproduction, the net-energy use intensity (EUI) is 4.60 kBtu/ft2y (14.5 kWh/m2y). This is a 95% EUI reduction over thenational institutional average and can be further reduced withadditional (ongoing) commissioning efforts. Suggested improvementsin operation include ensuring the electricity production isoptimized and any faults corrected, dimming electric lightingwhen daylight is sufficient, extending the hours of natural ventilation,and better utilization of the hydronic radiant slab for thermalstorage using predictive controls. This paper discusses theprocess followed in the design of the library, its key features, itsearly performance, and some of the lessons learned.
File Size : 1 file , 8.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-AT-19-008
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

Finite Element Analysis of Elastomers
Published Date: 01/01/1999
$39.3