BA-92-03-3 -- Analysis of the Dynamic Energy Performance of an HVAC System by Combining Simulations and Measurements PDF

BA-92-03-3 -- Analysis of the Dynamic Energy Performance of an HVAC System by Combining Simulations and Measurements PDF

Name:
BA-92-03-3 -- Analysis of the Dynamic Energy Performance of an HVAC System by Combining Simulations and Measurements PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Presents an analysis, based on combined monitoring and simulation of the dynamic interaction between HVAC system in operation and an occupied office room. The detailed two-week monitoring, including surface and room air temperatures and energy flows, was carried out in an occupied office room. Measured variables, such as ambient temperature, solar irradiation, heat gain by lights, etc, were used as input data for the simulations. An analysis of possible discrepancies between expected performance and monitored performance is thereby facilitated. The building in question has a variable-air-volume (VAV) system for individual room temperature control. The measured air temperature of the room is 23 deg + or - 0.3 deg C. The analysis of the data monitored and the simulation results indicate that the thermal peak demand would decrease during periods of high heat loads with the heater turned off completely and the supply air flow reduced. A somewhat larger room air temperature variation also must be permitted then. The alternative system design, a constant-air-volume (CAV) system, would reduce the thermal peak demand from 350 W to 135 W for the supply air system exclusively. The analysis indicates that the energy stored in the structure may be more efficiently utilised if a greater room temperature variation, 22 deg C + or - 1 deg C, is permitted. The simulations were made using a Swedish simulation program for building thermal behaviour. Comparisons between monitored and simulated data correlate well.

KEYWORDS: heating, ventilation, air conditioning, calculating, monitoring, measuring, energy consumption, performance, offices, rooms, buildings, surface temperature, air temperature, ambient temperature, solar radiation, heat gain, lighting, variable volume air conditioning, computer programs, comparing


File Size : 1 file , 860 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17852
Published : 1992

History


Related products


Best-Selling Products

AIHA AEAB06-715
Published Date: 01/01/2006
Essential Air Monitoring Methods (MAK-Collection for Occupational Health and Safety)
$62.4
AIHA AEAG00-382
Published Date: 01/01/2000
Investigations: A Handbook for Prevention Professionals
$31.8
AIHA AEAG07-726
Published Date: 01/01/2007
Guidance for Conducting Control Banding Analyses
$36
AIHA AEAG99-381
Published Date: 01/01/2000
User's Guide to A Strategy for Assessing and Managing Occupational Exposures
AIHA AEAH07-725
Published Date: 01/01/2007
Preventing Hazards at the Source
$36.3
AIHA AEAH10-559
Published Date:
2010 ERPG & WEEL Handbook
$17.4