BA-92-10-3 -- Uncertainties in the Evaluation of Window SHGC and U-Values Measured Using an Indoor Solar Simulator Facility PDF

BA-92-10-3 -- Uncertainties in the Evaluation of Window SHGC and U-Values Measured Using an Indoor Solar Simulator Facility PDF

Name:
BA-92-10-3 -- Uncertainties in the Evaluation of Window SHGC and U-Values Measured Using an Indoor Solar Simulator Facility PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

To determine the U-value and solar heat gain coefficient (SHGC) of window systems, the Solar Calorimetry Laboratory (SCL) has developed a unique laboratory test method based on the use of solar simulator test facility. The SCL procedure includes two distinct parts - the experimental measurement of the thermal performance, n, of window samples and the computation of their thermal characteristics, SHGC and U-value, from the performance test results. To evaluate the possible sources of error related to this test method and their magnitude, an uncertainty analysis was conducted. The uncertainties on the SHGC and U-values were computed based on estimates of the uncertainties in the experimental measurements. To assess the effects of the uncertainty in these measurements on the SHGC, a sensitivity analysis was conducted, and the dominant terms in the uncertainty equation were identified. To illustrate the range of typical uncertainties, three commercially available windows were considered - a single-glazed low-performance (LP) window, a typical double-glazed unit, and a high-performance (HP) window. Results show that, in the case of HP windows, the U-value uncertainty is approximately 8%, which corresponds to 3.5 W/m2 of heat flux under ASHRAE winter design conditions.

KEYWORDS: calculating, windows, transmittance, measuring, solar heat gain, laboratory testing, heat flow, performance, thermal properties, accuracy, double glazing, comparing


File Size : 1 file , 760 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17928
Published : 1992

History


Related products


Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
$12.9
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
$5.4
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
$23.7
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
$18.9
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
$22.2
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
$22.2