BN-97-06-5 -- The Memorial Tunnel Fire Ventilation Test Program: The Full Transverse Tests PDF

BN-97-06-5 -- The Memorial Tunnel Fire Ventilation Test Program: The Full Transverse Tests PDF

Name:
BN-97-06-5 -- The Memorial Tunnel Fire Ventilation Test Program: The Full Transverse Tests PDF

Published Date:
1997

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A number of tests of the Memorial Tunnel Fire Ventilation Test Program were devoted to determining the effectiveness of a full-transverse ventilation system in limiting the spread of smoke and hot gases, with varying system configurations and air flow rates. The controlled fire, located at the approximate quarter point of the 2,800ft (854m) long tunnel, was varied in three levels of intensity; 10, 20 and 50 megawatts (MW). Heavily insulated instrument "trees" at fixed cross-sectional locations throughout the roadway and in the plenum above the ceiling were equipped with thermocouples, bidirectional pitot tubes, and gas sampling tubes. The data-acquisition system (DAS) in a control trailer remote from the tunnel continuously recorded air temperatures, air velocities, and gas concentrations for subsequent analysis. A closed-circuit television (CCTV) system, composed of seven cameras inside the tunnel and immediately adjacent to its portals, facilitated observation of smoke movement at the monitors, which were also located in the control trailer. A total of 19 full-transverse tests were conducted - 9 with balanced supply-exhaust air flow rates and 10 with an imbalanced system configuration in which the exhaust flow rate exceeded the forced supply flow rate, causing the make-up air to be introduced through the tunnel portals. Addresses results and conclusions drawn by the author on the basis of acquired data and observations as an eyewitness to these tests as a member of the joint test group.

Units: Dual

KEYWORDS: year 1997, Testing, smoke ventilation, fire, tunnels, USA, comparing, roads


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-16652
Published : 1997

History


Related products


Best-Selling Products

VG 95370-10
Published Date: 12/01/1983
Electromagnetic Compatibility; Electromagnetic Compatibility of & in Systems - Test Method for Interference Currents
VG 95374-1
Published Date: 11/01/1992
Electromagnetic Compatibility (EMC) including Electromagnetic Pulse (EMP) and Lightning Protection - Program and Procedures - Administrative Regulations