Name:
BN-97-08-2 -- Residential Vertical Geothermal Heat Pump System Models: Calibration to Data PDF
Published Date:
1997
Status:
Active
Publisher:
ASHRAE
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitor data taken from a family housing unit located at Fort Polk, Louisiana. This simulation model represents the housing unit's geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was "tuned" to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
Units: Dual
KEYWORDS: year 1997, Heat pumps, geothermal energy, calibrating, monitoring, housing, USA, soil heat exchangers, measuring, domestic, calculating, comparing
| File Size : | 1 file , 2 MB |
| Note : | This product is unavailable in Russia, Belarus |
| Number of Pages : | 15 |
| Product Code(s) : | D-16674 |
| Published : | 1997 |