BN-97-11-3 -- Electrical Energy and Demand Savings from a Geothermal Heat Pump Energy Savings Performance Contract at Fort Polk, Louisiana PDF

BN-97-11-3 -- Electrical Energy and Demand Savings from a Geothermal Heat Pump Energy Savings Performance Contract at Fort Polk, Louisiana PDF

Name:
BN-97-11-3 -- Electrical Energy and Demand Savings from a Geothermal Heat Pump Energy Savings Performance Contract at Fort Polk, Louisiana PDF

Published Date:
1997

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

At Fort Polk, Louisiana, the space conditioning systems of an entire city (4,003 military family housing units) have been converted to geothermal heat pumps (GHPs) under an energy savings performance contract. At the same time, other efficiency measures, such as compact fluorescent lights, low-flow hot water outlets, and attic insulation, were installed. Pre- and post-retrofit data were taken at 15-minute intervals on energy flows through the electrical distribution feeders that serve the family housing areas of the post. Fifteen-minute-interval data were also taken on energy use from a sample of the residences. The analysis presented shows that for a typical meteorological year, the retrofits result in electrical energy savings of approximately 25.6 million kWh, or 32.4% of the pre-retrofit electrical use in family housing. Peak electrical demand has also been reduced by about 6.8 MW, which is 40% of pre-retrofit peak demand. In addition, the retrofits save about 260,000 therms per year of natural gas. It should be noted that the energy savings presented are the "apparent" energy savings observed in the monitored data and are not to be mistaken for the "contracted" energy savings used as the basis for payments. To determine the "contracted" energy savings, the "apparent" energy savings may require adjustments for such things as changes in indoor temperature performance criteria, additions of ceiling fans, and other factors.

Units: I-P

KEYWORDS: year 1997, Electricity consumption, energy conservation, energy consumption, geothermal energy, heat pumps, performance, modernising, peak load, measuring, military works, housing, case studies


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 15
Product Code(s) : D-16710
Published : 1997

History


Related products


Best-Selling Products

AREMA C&S MANUAL
Published Date: 01/01/2021
Communications & Signals Manual - 5-Volume set
AREMA COMM & SIGN
Published Date: 01/01/2018
COMMUNICATIONS & SIGNALS MANUAL - 5-VOLUME SET
AREMA COMM & SIGN
Published Date: 01/01/2019
COMMUNICATIONS & SIGNALS MANUAL - 5-VOLUME SET
AREMA MANUAL FOR RAILWAY ENGINEERING COMBO SET
Published Date: 01/01/2016
Manual for Railway Engineering - Combination Set - Print Version and CD-ROM
$887.4
AREMA MANUAL FOR RAILWAY ENGINEERING
Published Date: 01/01/2021
Manual for Railway Engineering
AREMA PRACTICAL GUIDE TO RAILWAY ENGINEERING COMBO SET
Published Date: 01/01/2016
PRACTICAL GUIDE TO RAILWAY ENGINEERING PLANS - Combination Set (Combination Book/CD-ROM)