Building Design and Operational Choices that Impact Indoor Exposures to Outdoor Particulate Matter inside Residences PDF

Building Design and Operational Choices that Impact Indoor Exposures to Outdoor Particulate Matter inside Residences PDF

Name:
Building Design and Operational Choices that Impact Indoor Exposures to Outdoor Particulate Matter inside Residences PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Although many associations have been observed between elevated outdoor airborne particulate matter concentrations and adverse healtheffects in large epidemiological studies, much of human exposure to particles of outdoor origin actually occurs indoors where we spend most of ourtime (and often at home). Two important influences on indoor concentrations of outdoor pollutants inside residences are (i) building envelopeconstruction and (ii) HVAC filter selection. This work describes recent experimental research on the impacts of both of these influencing factorson indoor concentrations of airborne particulate matter in residential buildings. Building envelope penetration factors (P) of submicron (20-1000nm) particles were recently measured in 19 single-family homes in Austin, TX that relied on natural infiltration for ventilation air. Values of Pranged from 0.17+/-0.03 to 0.72+/-0.08 and were significantly higher in older and leakier homes (as characterized by blower door tests). Anadditional experiment was also performed in the tightest, newest, net-zero-energy-capable home when it had an energy recovery ventilator (ERV)operating and connected to an outdoor air supply. This particular condition resulted in the largest penetration factor of the entire study: P =0.78+/-0.09. Therefore, the same home was responsible for both the least amount of outdoor particle infiltration and the most amount of outdoorparticle infiltration in this sample of homes, depending entirely on HVAC system design and operation. Indoor particle loss rates were alsomeasured in this study in each home and increased systematically with rated filter efficiency, from 0.92+/-0.46 per hour with low-efficiency(MERV < 5) filters installed to 1.09+/-0.60 and 2.32+/-1.03 per hour with medium (MERV 6-8) and high-efficiency (MERV greater than 10) filtersinstalled, respectively. Taken together, these measured values of outdoor particle sources and losses suggest that an occupant's indoor exposure tooutdoor particulate matter can vary by a factor of at least 60, depending on building envelope design, filter choice, and HVAC system design andoperation.


File Size : 1 file , 390 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 5
Product Code(s) : D-2013IAQConf-54
Published : 2013

History


Related products


Best-Selling Products

AFS 3D PPSCP
Published Date:
The 3D Printed Precision Sand Casting Process
$22.5
AFS 3DSPB
Published Date:
3D Sand Printing Benefits
$54.6
AFS 3DSPCD
Published Date:
3D Sand Printing Casting Design
$54.6
AFS 3DSPMD
Published Date:
3D Sand Printing Mold Quality
$54.6
AFS 3DSPPT
Published Date:
3D Sand Printing Process and Terminology
$54.6
AFS ACA
Published Date:
Aluminum Casting Alloys
$54.6