Buildings XI Conference -- Reconsidering the Approach towards Determining Overall Building EnclosureThermal Performance for Code Compliance PDF

Buildings XI Conference -- Reconsidering the Approach towards Determining Overall Building EnclosureThermal Performance for Code Compliance PDF

Name:
Buildings XI Conference -- Reconsidering the Approach towards Determining Overall Building EnclosureThermal Performance for Code Compliance PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

With each building code update and revision of ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings, and ANSI/ASHRAE Standard 90.2, Energy-Efficient Design of Low-Rise Residential Buildings, building enclosure thermal performance criteria are becoming more stringent to reduce building energy consumption. It is well understood that two-dimensional heat transfer must be considered in determining the U-factor of certain building enclosure assemblies (e.g., steel-stud-framed walls with batt insulation). However, the current approach to energy code calculations lacks guidance and/or requirements for

  • Whole-wall U-factors versus clear-wall U-factors (Kosny and Desjarlais 1994), including inside and outside corners, additional framing around windows and doors, and top and bottom track for framed walls
  • Including two- and three-dimensional heat transfer effects between assemblies (e.g., the effect of a cantilevered concrete slab on the wall U-factor, steel shelf angles)
  • U-factors of fenestration products as installed, rather than NFRC Standard 100, Procedure for Determining Fenestration Product U-Factor, values for standard-sized products, which is intended for side-by-side comparison of fenestration product, and are not typically representative of those actually used on most projects

Such simplifications can result in overestimating building thermal performance. With the ultimate goal of analyzing and demonstrating realistic energy conservation, rather than conservation predicted by oversimplified models, it is imperative that designers consider whole-wall R-values, two- and three-dimensional (2D and 3D) interaction of assemblies, and actual glazing assembly U-factors. This paper discusses and presents how current methods for U-factor calculations are insufficient through the use of examples, and proposes more detailed methods for calculating U-factors that include recognition of construction practices to be considered future revisions of energy codes and ASHRAE standards. Previously, the lack of software and computing power made conducting more detailed calculations including 2- and 3D thermal analysis unrealistic. However, today the necessary software and computing power exists, making it feasible to require more detailed calculations.


File Size : 1 file , 4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-BUILDINGSXI-137
Published : 2010

History


Related products


Best-Selling Products

SPI AQ-103
Published Date: 01/01/1994
Cosmetic Specifications of Injection Molded Parts
SPI AR-101
Published Date: 10/01/1996
Customs and Practices of the Moldmaking Industry
SPI AU 123
Published Date: 01/01/1992
Visual Evaluation of Reflected Color (Formerly PB-1)
SPI B151.1-1997
Published Date: 01/01/1997
Plastics Machinery - Horizontal Injection Molding Machines - Safety Requirements for Manufacture, Care, and Use
$11.1
SPI B151.15-2003
Published Date: 01/01/2003
Extrusion Blowmolding Machines - Safety Requirements for the Manufacture Care and Use
$13.8
SPI B151.2-1999
Published Date: 01/01/1999
Film Casting Machines - Construction, Care, and Use (revision and redesignation of ANSI B151.2-1982 (R1988))
$9.9