Buildings XI Conference -- The Hygrothermal Performance of Wood-Framed Wall Systems Using Spray Polyurethane Foam Insulations and a Smart Vapor Retarder in the Pacific Northwest PDF

Buildings XI Conference -- The Hygrothermal Performance of Wood-Framed Wall Systems Using Spray Polyurethane Foam Insulations and a Smart Vapor Retarder in the Pacific Northwest PDF

Name:
Buildings XI Conference -- The Hygrothermal Performance of Wood-Framed Wall Systems Using Spray Polyurethane Foam Insulations and a Smart Vapor Retarder in the Pacific Northwest PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
The US Pacific Northwest building codes require vapor retarders or barriers used in residential building walls to prevent moisture-related damages due to the moderate temperatures and high moisture levels caused by precipitation and relative humidity throughout the year. Research on wood-framed wall systems with exterior stucco and cavity spray polyurethane foams is being conducted in this climate zone. Two stucco-clad wall systems have been installed side by side in a natural-exposure testing facility in the Seattle, WA, area. One wall is insulated with a hybrid insulation system comprised of 2 in. spray polyurethane closed-cell foam and unfaced fiberglass batts. The closed-cell foam works in place of a separate vapor retarder due to its low water vapor transmission property, and at the same time offers good airtightness and thermal resistance. The other wall is insulated with 6 in. of open cell foam and has a variable-vapor-resistance "smart vapor" retarder attached to the interior surfaces of the foam and gypsum layer. Contrary to common building practice, the application of interior wall cavity foam requires careful moisture design. The results from the field tests confirm the critical role of the highly absorptive cladding and at the same time the use of cavity spray foam insulations. The results are being extended using a hygrothermal simulation tool. The field test data are compared to the simulation tool for both walls. This paper will describe the performance of these two walls and the need for clear design guidance for application in the Pacific Northwest.
File Size : 1 file , 3.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-BUILDINGSXI-129
Published : 2010

History


Related products


Best-Selling Products

AAMI 11135:1994
Published Date: 05/01/1994
Medical Devices - Validation and Routine Control of Ethylene Oxide Sterilization - Includes Errata
$29.7
AAMI 11607:1997
Published Date: 02/24/1997
Packaging for terminally sterilized medical devices
AAMI 11663:2014
Published Date: 08/08/2014
Quality of dialysis fluid for hemodialysis and related therapies
AAMI 11737-1
Published Date: 09/01/1995
Sterilization of Medical Devices - Microbiological Methods - Part 1: Estimation of the Population of Microorganisms on Product
$26.4
AAMI 11737-2
Published Date: 09/01/1998
Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
$26.4
AAMI 13958:2014
Published Date: 08/15/2014
Concentrates for hemodialysis and related therapies