Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Name:
Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Different types of phase-change materials (PCMs) have been tested as dynamic components in buildings during the last four decades. Most historical studies have found that PCMs enhance building energy performance. Some PCM-enhanced building materials, like PCM-gypsum boards or PCM-impregnated concretes, have already found limited applications in different countries. Today, continued improvements in building envelope technologies suggest that throughout southern and central US climates, residences may soon be routinely constructed with PCM in order to maximize insulation effectiveness and maintain low heating and cooling loads. This paper presents experimental and numerical results from thermal performance studies. These studies focus on blown fiberglass insulation modified with a novel spray-applied microencapsulated PCM. Experimental results are reported for both laboratory-scale and full-sized building elements tested in the field. In order to confirm theoretical predictions, PCMenhanced fiberglass insulation was evaluated in a guarded hot-box facility to demonstrate heat flow reductions when one side of a test wall is subjected to a temperature increase. The laboratory work showed reductions in heat flow of 30% due to the presence of approximately 20 wt % PCM in the insulation. Field testing of residential attics insulated with blown fiberglass and PCM was completed in Oak Ridge, Tennessee. Experimental work was followed by detailed whole building EnergyPlus simulations in order to generate energy performance data for different US climates. In addition, a series of numerical simulations and field experiments demonstrated a potential for application of a novel PCM fiberglass insulation as enabling technology to be used during the attic thermal renovations.
File Size : 1 file , 4.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-BUILDINGSXI-198
Published : 2010

History


Related products


Best-Selling Products

LPI 175
Published Date: 01/01/2008
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2008 Edition
LPI 175
Published Date: 2011
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2011 Edition
$14.7
LPI 175
Published Date: 2014
Standard of Practice for the Design - Installation - Inspection of Lightning Protection Systems, 2014 Edition
$14.7