Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Name:
Buildings XI Conference -- Theoretical and Experimental Thermal Performance Analysis of Building Shell Components Containing Blown Fiberglass Insulation Enhanced with Phase-Change Material (PCM) PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Different types of phase-change materials (PCMs) have been tested as dynamic components in buildings during the last four decades. Most historical studies have found that PCMs enhance building energy performance. Some PCM-enhanced building materials, like PCM-gypsum boards or PCM-impregnated concretes, have already found limited applications in different countries. Today, continued improvements in building envelope technologies suggest that throughout southern and central US climates, residences may soon be routinely constructed with PCM in order to maximize insulation effectiveness and maintain low heating and cooling loads. This paper presents experimental and numerical results from thermal performance studies. These studies focus on blown fiberglass insulation modified with a novel spray-applied microencapsulated PCM. Experimental results are reported for both laboratory-scale and full-sized building elements tested in the field. In order to confirm theoretical predictions, PCMenhanced fiberglass insulation was evaluated in a guarded hot-box facility to demonstrate heat flow reductions when one side of a test wall is subjected to a temperature increase. The laboratory work showed reductions in heat flow of 30% due to the presence of approximately 20 wt % PCM in the insulation. Field testing of residential attics insulated with blown fiberglass and PCM was completed in Oak Ridge, Tennessee. Experimental work was followed by detailed whole building EnergyPlus simulations in order to generate energy performance data for different US climates. In addition, a series of numerical simulations and field experiments demonstrated a potential for application of a novel PCM fiberglass insulation as enabling technology to be used during the attic thermal renovations.
File Size : 1 file , 4.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-BUILDINGSXI-198
Published : 2010

History


Related products


Best-Selling Products

NFSI B101.0-2017
Published Date: 01/11/2017
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.0-2021
Published Date: 03/12/2021
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.1-2009
Published Date: 10/13/2009
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.1-2020
Published Date: 2020
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.2-2020
Published Date: 2020
Test Method for Determining the Impact on Wet Coefficients of Friction of Various Chemical or Physical Walkway Surface Cleaners and Treatments on Common Hard-Surface Flooring Materials
$18
NFSI B101.3-2012
Published Date: 01/18/2012
Test Method for Measuring Wet DCOF of Common Hard-Surface Floor Materials
$18