C042 -- Development and Validate an Occupant-Centric Control of An Integrated Air and Domestic Hot Water System for Residential Buildings PDF

C042 -- Development and Validate an Occupant-Centric Control of An Integrated Air and Domestic Hot Water System for Residential Buildings PDF

Name:
C042 -- Development and Validate an Occupant-Centric Control of An Integrated Air and Domestic Hot Water System for Residential Buildings PDF

Published Date:
2023

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
New York State has over 750,000 residential units with inefficient HVAC and domestic hot water supplies. The potential for energy saving through occupancy control of ventilation and hot water system varies from 5% to 20%. In this study, we investigated the energy saving of occupancy control for an integrated air and domestic hot water system that could meet all the heating, cooling, and ventilation requirements for a single-family residential unit. We first collected the outdoor weather data, and air temperature and heating load or each room of a lab-based house equipped with this system at Syracuse University. Then, we built the thermal resistance-capacitance (RC) network model of this residential unit. It contained four thermal zones with a living room, two bedrooms and a bathroom. Next, we implemented the room occupancy profiles to each room for occupancy control. The occupancy control enabled the ventilation system work to meet the temperature set point only when the room was occupied. The measured and simulated results showed that the there was around 13% heating and 35% cooling energy reduction compared to the energy consumption with the conventional fiexed point control. The total cost for this occupancy control system was about $212 and the payback period was about 0.25 years.The future work includes implementing the occupancy control for this system with hot water usage in actual residential unit to further test the performance.
File Size : 1 file , 2.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-AT-23-C042
Published : 2023
Units of Measure : Dual

History


Related products


Best-Selling Products

AAMI 11135:1994
Published Date: 05/01/1994
Medical Devices - Validation and Routine Control of Ethylene Oxide Sterilization - Includes Errata
$29.7
AAMI 11607:1997
Published Date: 02/24/1997
Packaging for terminally sterilized medical devices
AAMI 11663:2014
Published Date: 08/08/2014
Quality of dialysis fluid for hemodialysis and related therapies
AAMI 11737-1
Published Date: 09/01/1995
Sterilization of Medical Devices - Microbiological Methods - Part 1: Estimation of the Population of Microorganisms on Product
$26.4
AAMI 11737-2
Published Date: 09/01/1998
Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
$26.4
AAMI 13958:2014
Published Date: 08/15/2014
Concentrates for hemodialysis and related therapies