C27 -- Energy Saving By Using Mains Water Adiabatic Cooling Retrofit Kit For Dry Heat Rejection Equipments PDF

C27 -- Energy Saving By Using Mains Water Adiabatic Cooling Retrofit Kit For Dry Heat Rejection Equipments PDF

Name:
C27 -- Energy Saving By Using Mains Water Adiabatic Cooling Retrofit Kit For Dry Heat Rejection Equipments PDF

Published Date:
2022

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Air-cooled heat rejection systems (air-cooled condensers, chillers and dry coolers) rely on dry bulb temperature which is generally between5C (41F) and 15C (59F) higher than the wet bulb temperatures. Traditionally, large heat rejection systems use cooling towers orevaporative coolers in order to reduce the heat rejection equipment size, as well as the overall energy consumption due to lower condensingtemperatures. However, the water-based corrosion, maintenance and health risks such as Legionella disease have moved the industrytowards less efficient dry heat rejection systems.

Through the simple addition of intermittently sprayed water over a wired mesh area in front of the heat rejection surface against thedirection of the air stream, it is possible to introduce wet bulb temperatures during only peak high ambient periods. An adiabaticcooling process can be introduced through using simple city main water into an air stream which rapidly evaporates and the hiddenenergy within the water can provide a cooler downstream air temperature as much as 10~25C (2~30F) lower than the ambientincoming air. Lower air on temperature results in lower condensing temperature and therefore makes it possible to save as much as30% peak power consumption by simply using water directly from the tap.

The majority of the time the water presence remains within the sealed main water pipe and is based on utilizing a Total Wasteprinciple. Hence, the health risk involved with a standing water reservoir as well as expensive chemical treatment requirements can becompletely eliminated.

Test sites of this new concept indicated between 20~35% peak electricity reduction for Air Cooled Chillers and Condensers. Thisconcept can be manufactured and considered as a simple DIY kit for both new and retrofit applications. Hence, the potential for theenergy saving and Carbon Emission reduction for the industry as a whole is significant and this can be achieved by the simple use ofany potable water source. 

File Size : 1 file , 4.8 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-ICEB22-27
Published : 2022
Units of Measure : Dual

History


Related products


Best-Selling Products

ASNT 0008
Published Date: 2004
Radiographic Interpretation
ASNT 0140
Published Date: 2012
Nondestructive Testing Handbook, Vol. 10: Overview, 3rd ed.
$54.6
ASNT 0141
Published Date: 2017
Nondestructive Testing Handbook, Vol. 2: Leak Testing (LT), 4th ed.
$61.8
ASNT 0141
Published Date: 1997
Nondestructive Testing Handbook, Third Edition: Volume One, Leak Testing
ASNT 0142
Published Date: 1999
Nondestructive Testing Handbook - Third Edition - Volume 2: Liquid Penetrant Tests