CFD Analysis for Air Conditioning System for Outdoor Environment PDF

CFD Analysis for Air Conditioning System for Outdoor Environment PDF

Name:
CFD Analysis for Air Conditioning System for Outdoor Environment PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Designing a HVAC system to meet the demands of architect for creating and maintaining a microclimate thermal comfort is a challenge at many fronts. Human thermal comfort is the ultimate goal of the system. Furthermore, condensation, humidity level and air velocity have to be controlled in order to provide for a one-of-kind outdoor experience. The wellness center is comprised of a number of rooms each with a specific purpose/service (example: oxygen bar, massage, skylight terrace etc), indoor features (water pond, live plants) and misting stations.

The HVAC design for this project incorporates conventional duct-delivered conditioned air system and under floor cooling and heating system. Computational Fluid Dynamics (CFD) simulations are performed on the submitted HVAC design to investigate thermal comfort within the indoor environment of the wellness center building at a resort in Qatar. CFD is a flexible tool for predicting system performance for a given flow system. In this paper, various system configurations for the wellness center were explored and simulated with CFD.

Thermal CFD analysis is performed for the full-scale 3-D model of the wellness center. In close coordination with architect, designer and concerned MEP contractor, a full-scale geometry was prepared taking into account all the features in the construction which will directly contribute to the HVAC performance. External climate criteria is considered as the wellness center is connected to the external environment through louvers on facade, the percentage opening of which is to be controlled relative to outdoor conditions in order to maintain a certain moist microclimate indoors.


File Size : 1 file , 3.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-2014FICEConf-2-1
Published : 2014

History


Related products


Best-Selling Products

RIA-A3 R15.05-1-1990 (R1999)
Published Date: 01/01/1999
Evaluation of Point-to-Point and Static Performance Characteristics of Industrial Robots and Robot Systems
RIA-A3 R15.05-2-1992 (R1999)
Published Date: 01/01/1999
Industrial Robots and Robot Systems - Path-Related and Dynamic Performance Characteristics - Evaluation
RIA-A3 R15.05-3-1992 (R1999)
Published Date: 01/01/1999
Industrial Robots and Robot Systems - Reliability Acceptance Testing - Guidelines
RIA-A3 R15.06-1999 (R2009)
Published Date: 01/01/1999
Industrial Robots and Robot Systems - Safety Requirements
RIA-A3 R15.06-2012
Published Date: 03/28/2013
Industrial Robots and Robot Systems - Safety Requirements
$97.5
RIA-A3 R15.08-1-2020
Published Date: 12/25/2020
Industrial Robots and Robot Systems - Safety Requirements Part 1: Requirements for the Industrial Mobile Robot
$67.5