CH-09-051 -- Impact of Pressurization on Energy Consumption for Laboratories and Cleanrooms PDF

CH-09-051 -- Impact of Pressurization on Energy Consumption for Laboratories and Cleanrooms PDF

Name:
CH-09-051 -- Impact of Pressurization on Energy Consumption for Laboratories and Cleanrooms PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Pressure differential setpoint and air tightness affect both pressure control and energy consumption for containment spaces such as laboratories and cleanrooms. Due to the lack of engineering means to determine the suitable pressure differential setpoint during the design stage, such a setpoint is often intuitively selected. There is a lack of study in the literature that quantitatively examines the impacts of pressure differential setpoint and air tightness on energy consumption for containment spaces. Therefore, the objective of this study is to use simulation models to quantify the impact of pressure differential and air tightness on HVAC system energy consumption for a containment space. In this paper, three different laboratory layouts—a single laboratory, a suite of pressurized laboratories consisting of a small space within a large space, and two adjacent pressurized laboratory spaces— are modeled and simulated using MATLAB SIMULINK (Mathworks 2007). Using the simulation models, pressure differential for each laboratory space is systematically varied from –0.01 in. w.c. to –0.1 in. w.c. for each layout. Air tightness is also systematically changed from 500–3500 cfm/(in. w.c.)0.65 (which is equivalent to 0.16–1.1 cfm/ft2 at 0.3 in. w.c.) to represent a very-tight to very-loose envelope for each laboratory space within each layout. In general, the envelope air tightness affects fan and coil energy consumption greatly. Pressure differential setpoint also affect fan and coil energy consumption. It is found that for the single laboratory space layout, every 0.01 in. w.c. pressure differential setpoint variation yields about 2%–3% total energy consumption change. For every 500 cfm/(in. w.c.)0.65 air tightness variation, total energy consumption changes about 10%. For Layout 2, a suite of pressurized laboratory spaces consisting of a small inner space in a large outer space, pressure differential setpoint and air tightness variations in the inner small laboratory space cause larger energy changes than any variation in the outer large laboratory space. For Layout 3, two adjacent pressurized laboratory spaces, the energy impacts of differential setpoint and air tightness from the two spaces are similar, even though space 1 is about half the size of space 2. In general, every 0.01 in. w.c. pressure setpoint increase yields about 1%–2% total energy consumption change. For every 500 cfm/(in. w.c.)0.65 air tightness variation, total energy consumption changes about 10%.

Units: Dual

 


File Size : 1 file , 3.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-CH-09-051
Published : 2009

History


Related products


Best-Selling Products

NS-EN ISO/CIE 11664-1:2019
Published Date: 10/01/2019
Colorimetry - Part 1: CIE standard colorimetric observers (ISO/CIE 11664-1:2019)
NS-EN ISO/CIE 11664-2:2022
Published Date: 11/23/2022
Colorimetry - Part 2: CIE standard illuminants (ISO/CIE 11664-2:2022)
NS-EN ISO/CIE 11664-3:2019
Published Date: 10/01/2019
Colorimetry - Part 3: CIE tristimulus values (ISO/CIE 11664-3:2019)
NS-EN ISO/CIE 11664-5:2024
Published Date: 07/01/2024
Colorimetry - Part 5: CIE 1976 L*u*v* colour space and u', v' uniform chromaticity scale diagram (ISO/CIE 11664-5:2024)
NS-EN ISO/CIE 11664-6:2022
Published Date: 10/19/2022
Colorimetry - Part 6: CIEDE2000 colour-difference formula (ISO/CIE 11664-6:2022)