CH-12-017 -- Modeling the Performance of ECM and SCR Series Fan-Powered Terminal Units in Single-Duct VAV Systems PDF

CH-12-017 -- Modeling the Performance of ECM and SCR Series Fan-Powered Terminal Units in Single-Duct VAV Systems PDF

Name:
CH-12-017 -- Modeling the Performance of ECM and SCR Series Fan-Powered Terminal Units in Single-Duct VAV Systems PDF

Published Date:
2011

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Single-duct variable-air-volume systems often use series- and parallel-fan-powered terminal units to control the airflow in conditioned spaces. A laboratory-verified model of single-duct variable-air-volume systems was developed to simulate both series and parallel fan terminal units where the terminal unit fans are controlled by either silicon-controlled rectifiers or electronically commutated motors.

The paper provides the equation needed to simulate the performance of a fan-powered terminal unit. The simulation model developed here includes a five-zone office building whose performance was simulated in five cities in the United States: Houston, Phoenix, Chicago, New York, and San Francisco. The model includes total plant energy, total cooling plant energy, primary fan energy, terminal unit fan energy, and heat energy added.

The single-duct variable-air-volume simulation results showed that the reduction in the annual energy used by the office building with series-fan-powered terminal units having electronically commutated motors compared to series units having silicon-controlled rectifier-controlled motors varied by location. The largest energy savings for the building was in Phoenix (8.4%), while the smallest was in Chicago (5.9%). In all cases, the reduction in electricity used by the terminal unit fans with electronically commutated motors was near 65%. These results indicate that using fan-powered terminal units with electronically commutated motors offers the potential for sizable savings in energy compared to units with silicon-controlled rectifier-controlled motors


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-CH-12-017
Published : 2011

History


Related products


Best-Selling Products

AATCC 100-2004
Published Date: 01/01/2004
Antibacterial Finishes on Textile Materials: Assessment of
$18.6
AATCC 100-2004
Published Date: 2004
Antibacterial Finishes on Textile Materials: Assessment of (Editorial Revision 2009)
$19.8
AATCC 100-2012
Published Date: 2012
Antibacterial Finishes on Textile Materials: Assessment of
$21
AATCC 100-2019
Published Date: 2019
Antibacterial Finishes on Textile Materials: Assessment of
$21
AATCC 101-1999
Published Date:
Colorfastness to Bleaching with Hydrogen Peroxide
$18.6
AATCC 101-2004
Published Date: 01/01/2004
Colorfastness to Bleaching with Hydrogen Peroxide
$18.6