CH-12-034 (RP-1589) -- Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers, Part 1: Experimental Methodology PDF

CH-12-034 (RP-1589) -- Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers, Part 1: Experimental Methodology PDF

Name:
CH-12-034 (RP-1589) -- Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers, Part 1: Experimental Methodology PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper is based on findings resulting from ASHRAE Research Project RP-1589.

Microchannel heat exchangers with louvered folded finsare subjected to frequent frost and defrost cycles when used inoutdoor evaporator coils of air-source heat pump systems.Despite their potential for heat transfer enhancements, understandingthe root causes that penalize microchannel heatexchangers during frosting operating conditions is still anopen field of study.

This paper presents a new experimental methodology tostudy frost growth on louvered folded fins of microchannel heatexchangers. The paper demonstrates the feasibility of the frostmass and frost thickness measurements and, through a seriesof controlled laboratory experiments, provides new data forfrost growth on louvered fins. Fin surface temperature wasdirectly measured during actual frosting operating conditions,and relations with heat transfer rates, air-side pressure drops,and frosting cycle times are discussed. The experimentalresults suggested that the frost mass increased linearly withtime and that there was no measurable time delay before watervapor began to frost and accumulate on the fins. The air-sideflow blockage due to frost accumulation on the front leadingedge of the fins was strongly dependent on the fin surfacetemperature, and the data confirmed that the flow blockagewas the key factor for the heat transfer capacity degradationduring frosting operation.


File Size : 1 file , 4.8 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 15
Product Code(s) : D-CH-12-034
Published : 2012

History


Related products


Best-Selling Products

UNE-ISO/PAS 17001:2006 IN
Published Date: 03/15/2006
Conformity assessment. Impartiality. Principles and requirements
UNE-ISO/PAS 17002:2006 IN
Published Date: 03/15/2006
Conformity assessment - Confidentiality -- Principles and requirements
UNE-ISO/PAS 17003:2006 IN
Published Date: 03/15/2006
Conformity assessment - Complaints and appeals -- Principles and requirements
UNE-ISO/PAS 17004:2006 IN
Published Date: 03/15/2006
Conformity assessment. Disclosure of information. Principles and requirements
UNE-ISO/PAS 17005:2009 IN
Published Date: 12/16/2009
Conformity assessment . Use of management systems. Principles and requirements