CH-12-C040 -- Central Plant Energy Savings by Operator Training PDF

CH-12-C040 -- Central Plant Energy Savings by Operator Training PDF

Name:
CH-12-C040 -- Central Plant Energy Savings by Operator Training PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The central plant at the University of Southern Indiana currently serves 18 campus buildings over 300 acres. The central plant produces and circulates chilled water for air handlers at the individual buildings. The system includes primary chiller pumps, secondary circulation pumps to deliver flow throughout the campus and tertiary pumps in each campus building. The chilled water system consists of five chillers, a chilled waterstorage tank and a plate and frame heat exchanger that can be used when the outdoor air temperatures are low enough. The total capacity is 6500 tons of cooling.

The system has been added to numerous times over the past 40 years, by different engineering firms, each implementing different system considerations. Through the years, buildings and units have been added to the system, and HVAC operators have left and new ones have been hired, resulting in some inefficient practices. The physical plant manager initiated a request for updated training of the operators and analysis of the system to reduce energy expenses.

This paper discusses methods of energy savings that relate to the chilled water supply: a correction of improper use of the chilled water tank, the development of a graphical method for chiller staging, and the identification of system conditions that will result in negative readings from the differential pressure transmitter that is used to control the secondary circulation pumps. Part of the system analysis was done as part of a seniorlevel thermal science class, which is also discussed. It has been demonstrated that HVAC system training for the operators can result in increased energy-efficiency in system operation.


File Size : 1 file , 880 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-CH-12-C040
Published : 2012

History


Related products


Best-Selling Products

NAVY AN-T-74
Published Date: 08/16/1944
TAPE; SILK
$9
NAVY DI-ILSS-80833 CANC NOTICE 1
Published Date: 05/09/2022
DAMAGED RETROGRADE SCREENING REPORT
$8.1
NAVY DI-ILSS-80833
Published Date: 05/31/1989
DAMAGED RETROGRADE SCREENING REPORT
$16.2
NAVY DI-ILSS-80834 CANC NOTICE 1
Published Date: 05/09/2022
CONSUMABLE PARTS BONDROOM/INVENTORY AND PARTS USAGE REPORT
$8.1
NAVY DI-ILSS-80834
Published Date: 05/31/1989
CONSUMABLE PARTS BONDROOM/INVENTORY AND PARTS USAGE REPORT
$16.5
NAVY DI-ILSS-80835 CANC NOTICE 1
Published Date: 05/09/2022
COMMERCIALLY REWORKED END ITEMS, MONTHLY STATUS REPORT
$8.1