CH-24-C032 - Retrofit and Experimental Validation of a Packaged Air-Conditioning Unit with a Heat Exchanger Utilizing Shape- and Topology-Optimized Tube Bundles PDF

CH-24-C032 - Retrofit and Experimental Validation of a Packaged Air-Conditioning Unit with a Heat Exchanger Utilizing Shape- and Topology-Optimized Tube Bundles PDF

Name:
CH-24-C032 - Retrofit and Experimental Validation of a Packaged Air-Conditioning Unit with a Heat Exchanger Utilizing Shape- and Topology-Optimized Tube Bundles PDF

Published Date:
2024

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Air-to-refrigerant heat exchangers (HXs) are critical components in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. Improving the performance of such devices typically involves reducing the dominant airside thermal resistance using novel fin-and-tube shapes. Recent advancements in high-fidelity simulation tools and advanced manufacturing techniques have led researchers to apply shape and topology optimization to HX design problems, resulting in HX geometries with novel, non-round bare tube shapes which have the potential to outperform existing state-of-the-art HXs. In this paper, we present the retrofit and experimental testing of an 8.4 kW (2.4-Ton) R410A packaged air-conditioning (A/C) unit at AHRI test conditions retrofitted with a conventionally manufactured non-round bare tube evaporator prototype which utilizes shape and topology-optimized bare tubes with an airside hydraulic diameter of ~2-3 mm (0.08-0.12 in). The packaged A/C unit was first experimentally evaluated with its baseline tube-fin HXs installed, then retested after replacing the baseline evaporator with the new HX prototype as a drop-in replacement to determine the impact of this new type of HX on overall system performance. Experimental results show a ~10% reduction in cooling capacity and coefficient of performance (COP), with a 15% and 56% reduction in R410A charge and evaporator core envelope volume, respectively. This was mainly attributed to the evaporator being undersized for the application of interest. A system-level simulation model was built and calibrated using experimental data from baseline unit testing. It was found that that retrofitting the packaged A/C unit with properly-sized HXs can result in a retrofitted system with nearly identical performance to the baseline system with ~50% charge reduction, showing these new HXs can serve as a viable high performance, reduced charge drop-in replacement HX for the present application. The paper concludes by highlighting challenges and future recommendations.
File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-CH-24-C032
Published : 2024

History


Related products


Best-Selling Products

ABMA/ISO 10285-1992 (R2008)
Published Date: 01/01/1992
Rolling Bearings, linear motion, recirculating ball, sleeve type-Metric series
ABMA/ISO 104:2014
Published Date: 2014
Rolling bearings - Thrust bearings - Boundary dimensions, general plan
$13.2
ABMA/ISO 104-2016
Published Date: 01/01/1994
Rolling bearings - Thrust bearings - Boundary dimensions, general plan
ABMA/ISO 10A:2001 (R2020)
Published Date: 2001
Metal Balls for Unground Bearings and Other Issues
$16.5
ABMA/ISO 12240-1:1998 (S2010)
Published Date: 01/01/1998
Spherical Plain Bearings - Part 1: Radial Spherical Plain Bearings
$13.2
ABMA/ISO 12240-2:1998 (2010)
Published Date: 01/01/1998
Spherical plain bearings - Part 2: Angular contact spherical plain bearings
$13.2