CH-24-C059 - An Investigation into the Capability of Inverse Model-Based Algorithms for Monitoring Building Envelope Performance PDF

CH-24-C059 - An Investigation into the Capability of Inverse Model-Based Algorithms for Monitoring Building Envelope Performance PDF

Name:
CH-24-C059 - An Investigation into the Capability of Inverse Model-Based Algorithms for Monitoring Building Envelope Performance PDF

Published Date:
2024

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Building envelope performance monitoring is essential to track changes in envelope health and identify critical thermal transmittance and airtightness issues. Inverse model-based envelope characterization methods address the limitations of traditional envelope performance testing methods and allow for continuous monitoring of envelope health using available measurements from the building automation system. However, several challenges are associated with deploying these inverse models, including data collection and processing, practical implementation, and results interpretation. This paper investigates the capability of inverse model-based approaches for monitoring building envelope performance and provides practical guidance for implementing these models. The inverse model-based envelope characterization algorithms are validated using simulated data from a newly constructed academic building in Ottawa, Canada. The practical implementation of the models is demonstrated using data collected from an office building located in Borden, Canada. The data are used to train the inverse models and estimate the buildings' effective thermal transmittance and air permeance. Recommended values are extracted from building codes to quantify deviation from these codes and identify retrofit improvement opportunities. The results show that the inverse model-based methods could estimate thermal transmittance and air permeance with a -5% and 14% error, respectively. A potential reduction of 9% in the office building's heating demand is estimated upon upgrading the thermal transmittance to the current building code recommended values.
File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-CH-24-C059
Published : 2024

History


Related products


Best-Selling Products

prNS 2964
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polyethylene (PE) for underground non-pressure systems for drainage and sewerage
prNS 2965
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polypropylene (PP) for underground non-pressure systems for drainage and sewerage
prNS 2966
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of unplasticised poly(vinyl chloride) (PVC-U) for underground non-pressure systems for drainage and sewerage
prNS 2967
Published Date: 06/01/2001
Cable ducts of plastics with smooth solid wall pipe
prNS 2970
Published Date: 09/06/2004
Solid Wall cable ducting of thermoplastics for embedding
prNS 3563
Published Date: 07/01/2002
Ventilation for buildings - Design methodes for indoor climate