CH-24-C094 - A Comparative Analysis of Energy Performance of Ultra-Low Temperature District Heating and Cooling Networks with Different Substation Configurations PDF

CH-24-C094 - A Comparative Analysis of Energy Performance of Ultra-Low Temperature District Heating and Cooling Networks with Different Substation Configurations PDF

Name:
CH-24-C094 - A Comparative Analysis of Energy Performance of Ultra-Low Temperature District Heating and Cooling Networks with Different Substation Configurations PDF

Published Date:
2024

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
This study aims to explore the differences in the energy performance among ultra-low temperature district heating and cooling (ULTDHC) networks with different substation configurations. Three substation configurations, including free cooling (using heat exchangers only for substation cooling), active cooling (using chillers only for substation cooling), and hybrid cooling (utilizing both chillers and heat exchangers for substation cooling), are investigated through a simulation-based case study in Atlanta, GA. A detailed ULTDHC system model is developed using Modelica. The simulation results indicate that without integrating the sewage water, compared to the system with active cooling configuration, the system with free/hybrid cooling configuration exhibits annual electric energy savings of 5.5% for radiant systems and 2.6% for all-air systems, respectively. However, when the excess waste heat from the sewage water is recycled, the free cooling configuration performs the poorest among the three. In comparison to the system with free cooling, the system with hybrid cooling achieves energy savings of 4.0% for radiant systems and 4.7% for all air systems. These findings reveal that although substation free cooling makes it possible to reduce the energy consumed by the substation cooling process, the overall system performance varies depending on multiple factors such as the availability of thermal energy sources and building-side HVAC system requirements. In addition, the simulation results underscore that network operating temperature control plays a crucial role in the system's performance. Therefore, detailed system analyses are recommended to guide the selection of the most suitable configuration and temperature control settings during ULTDHC system design.
File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-CH-24-C094
Published : 2024

History


Related products


Best-Selling Products

NS-ISO/IEC/IEEE 12207:2017
Published Date: 10/01/2018
Systems and software engineering — Software life cycle processes
NS-ISO/IEC/IEEE 15026-4:2021
Published Date: 06/22/2021
Systems and software engineering - Systems and software assurance - Part 4: Assurance in the life cycle
NS-ISO/IEC/IEEE 15288:2015
Published Date: 11/01/2018
Systems and software engineering — System life cycle processes
NS-ISO/IEC/IEEE 15288:2023
Published Date: 05/30/2023
Systems and software engineering — System life cycle processes
NS-ISO/IEC/IEEE 16085:2021
Published Date: 02/05/2021
Systems and software engineering — Life cycle processes — Risk management
NS-ISO/IEC/IEEE 16326:2009
Published Date: 11/01/2018
Systems and software engineering - Life cycle processes - Project management