Name:
CH-81-09-1 -- Determination of Annual Efficiency of Vented Heaters Equipped with Thermally Activated Vent Dampers PDF
Published Date:
1981
Status:
Active
Publisher:
ASHRAE
Part-load space heater efficiency requires the determination of five flue losses. These are latent heat loss (LL), on-period sensible heat loss (LS,ON), on-period infiltration loss (LI,ON), off-period sensible heat loss (LS,OFF) and off-period infiltration loss (LI,OFF).
We determined:
-- Which of the part-load losses can be adequately measured using the current DOE procedure?
-- Which part load losses cannot be measured using the DOE procedure?
-- Seasonal efficiencies for three vented heaters using the current and a modified procedure.
All stack losses associated with the calculation of part-load utilization efficiency (nu) were reviewed in the development of a test method for heaters equipped with the thermally-activated vent damper. Annual fuel utilization efficiency and associated energy savings were determined for two thermal vent dampers tested with three types of gas-fueled heaters which operate in either the cycling mode or in the modulating fuel input mode.
Test results showed energy savings from 1 to 9% depending on the type of heater as well as the type of damper used.
| File Size : | 1 file , 1.4 MB |
| Note : | This product is unavailable in Russia, Belarus |
| Number of Pages : | 16 |
| Product Code(s) : | D-CH-81-09-1 |
| Published : | 1981 |