In fiscal year 1974/75 the central utilities plant at the University of California, San Diego (UCSD), consumed 171,360 million kcal (6.8 million therms) of boiler fuel. In 1979/80, the first full year of operation following installation of Dead Band Control Strategy (DBCS), the central utilities plant consumed 88,200 million kcal (3.5 million therms) of boiler fuel. The retrofit process began in 1976 and progressed one building at a time to final completion in February 1979. Funds were made available through the University of California Capital Improvement program for a total cost of $600,000. The cost avoidance this year is estimated at $1,520,000.

UCSD is the fourth largest campus of the University of California nine-campus complex, and is geographically separated into 3 parts : the main campus, Scripps Institution of Oceanography, and the Medical Center. This paper concerns only the main campus portion of UCSD. The main campus, built on the grounds of a World War II Marine Corps Facility known as Camp Matthews, is located about 1 mile from the Pacific Ocean and 12 miles north of downtown San Diego. The central utilities plant and 12 major buildings totaling 204,387 square meters (2,200,000 square feet) have been constructed on this site during the past 15 years.

Because UCSD is a major science and medical research institution, most buildings have sophisticated HVAC systems. There are more than 40 HVAC systems ranging in size from 5 to 150 fan hp (3.7 to 112 kW) and a total 9,000 tons of refrigeration (31,634 kW). Most buildings are arranged with pneumatic controls while some have electronic controls.


File Size : 1 file , 980 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 7
Product Code(s) : D-CH-81-11-2
Published : 1981

History


Related products


Best-Selling Products

AGA A25023
Published Date: 01/01/2005
2005 Handbook of Publicly Traded AGA Member Companies
57.00 €
AGA A25024
Published Date: 01/01/2006
2006 Handbook of Publicly Traded AGA Member Companies
57.00 €
AGA ANSI Z223.1-2024 / NFPA 54
Published Date: 2024
National Fuel Gas Code, 2024 Edition
28.20 €
AGA ANSI Z223.1 Set
Published Date: 01/01/2002
National Fuel Gas Code and Handbook Set, 2002 Edition
AGA ANSI Z223.1 Set
Published Date: 01/01/2006
National Fuel Gas Code and Handbook Set, 2006 Edition
AGA ANSI Z223.1 Set
Published Date: 2009
National Fuel Gas Code and Handbook Set, 2009 Edition
49.50 €