CH-95-03-1 -- Hygrothermal Performance Analysis of Wind Barrier Structures PDF

CH-95-03-1 -- Hygrothermal Performance Analysis of Wind Barrier Structures PDF

Name:
CH-95-03-1 -- Hygrothermal Performance Analysis of Wind Barrier Structures PDF

Published Date:
1995

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Wind barriers are used in structures that have air-permeable thermal insulation materials. Their main function is to prevent the pressure differences from causing air flow-related heat loss through the building envelope. Wind barriers should not contribute to moisture problems in structures by causing condensation or moisture accumulation. Presents requirements for the airtightness of wind barriers and results of the hygrothermal analysis of wind barrier structures. The studied wind barrier structures were typical for small houses in Finland - timber-framed structures with lightweight glass wool thermal insulation. The air permeances and the parameter sensitivities were studied numerically both for ideal and non-ideal structures. In ideal structures, the material layers were assumed to be tightly (ideally) connected to each other, but in non-ideal structures there were air leakage routes (air cracks) at the interfaces of thermal insulation and adjacent material layers. The drying of moisture through different wind barriers was analysed in laboratory experiments under boundary conditions similar to those in practice, e.g., with outdoor temperatures below and above 0degC. The measured moisture flows were compared with those derived from a wet-cup water vapour permeability test. Also, the liquid flow along the interface of the wind barrier and glass wool was studied in full-scale experiments with high moisture loads.

KEYWORDS: year 1995, performance, heat flow, measuring, thermal properties, air tightness, wind barriers, pressure difference, air flow, moisture, Finland, timber framed construction, thermal insulation, mineral wool, leaking, air infiltration, laboratory testing, measuring, comparing, experiment, air permeability, permeability


File Size : 1 file , 1.2 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16766
Published : 1995

History


Related products


Best-Selling Products

INCITS 100-1989(R1995) Add. 1:1991
Published Date: 01/01/1991
Addendum 1 to ANSI/NCITS X3.100-1989, Interface Between DTE & DCE for Packet Mode Operation with Packet Switch Data Communications Networks - NUI and NUI-Derived Facility Extensions (formerly ANSI X3.100-1989(R1995) Add.1:1991)
INCITS 100-1989(R1995)
Published Date: 01/01/1989
Interface Between DTE & DCE for Packet Mode Operation with Packet Switch Data Communications Networks (CCITT X.25) (formerly ANSI X3.100-1989(R1995)
INCITS 103-1983(R1996)
Published Date: 01/01/1983
Unrecorded Magnetic Tape Minicassette For Information Interchange, Coplanar 3.81 mm (0.150 Inch) (formerly ANSI X3.103-1983(R1996))
INCITS 11-1990(R2002)
Published Date: 01/01/1990
Specification for General Purpose Paper Cards for Information Interchange (formerly ANSI X3.11-1990(R2002))
$18
INCITS 111-1986(R1997)
Published Date: 01/01/1986
Matrix Character Sets for Optical Character Recognition (OCR-M) (formerly ANSI X3.111-1986(R1997))
INCITS 112-1984(R1996)
Published Date: 01/01/1984
14-Inch (356 mm) Diameter Low Surface Friction Magnetic Storage Disk (formerly ANSI X3.112-1984(R1996))