CH-99-12-1 -- Guidelines for the Application of Upper-Room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion - Part I: Basic Principles PDF

CH-99-12-1 -- Guidelines for the Application of Upper-Room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion - Part I: Basic Principles PDF

Name:
CH-99-12-1 -- Guidelines for the Application of Upper-Room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion - Part I: Basic Principles PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Upper-room ultraviolet germicidal irradiation (UVGI) holds the promise of greatly lowering the concentration of airborne organisms in the lower part of the room and thereby controlling the spread of airborne infection among occupants. The determinants of effectiveness in clearing the lower room air of infectious organisms are the UV irradiance in the upper air, the rate of air mixing between upper and lower zones, and the specific susceptibility of a microbe to UVGI. The germicidal dose is the product of irradiance times duration, and the two components are mutually interchangeable within wide limits. Control of eye exposure to UVGI, to avoid irritation, places practical limits on irradiance levels in occupied rooms, and room air circulation patterns govern irradiation time. Therefore, there must be careful consideration given to the placement of upper-room UVGI fixtures in relation to room geometry and ventilation mode to obtain maximal microbial destroying efficacy. Efficacy can be demonstrated and quantified by calculating the number of additional air changes that would have been required to obtain the same clearance rate of viable microbes that was produced by the installed UVGI alone. For normally ventilated rooms, the air exchange equivalent of well-installed upper-room UVGI is in the range of 10 to 20 air changes per hour for tubercle bacilli.

Units: SI


File Size : 1 file , 1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-7600
Published : 1999

History


Related products


Best-Selling Products

VDI/DGQ 3441
Published Date: 03/01/1977
Statistical Testing of the Operational and Positional Accuracy of Machine Tools; Basis
VDI/DGQ 3442
Published Date: 03/01/1977
Statical examination of exactly working of turing machines
VDI/DGQ 3443
Published Date: 03/01/1977
Statistical examination of exactly working of milling machines
VDI/DGQ 3444
Published Date: 09/01/1978
Statistical control of exactly working and positioning of coordinate drilling machines and machining centers
VDI/DGQ 3445 Sheet 1
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; fundamentels
VDI/DGQ 3445 Sheet 2
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; external cylindrical grinding machines with center points; plunge-cut grinding operation