CH-99-16-4 -- Control Strategies for Domestic Hot Water Recirculation Systems PDF

CH-99-16-4 -- Control Strategies for Domestic Hot Water Recirculation Systems PDF

Name:
CH-99-16-4 -- Control Strategies for Domestic Hot Water Recirculation Systems PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The purpose of a domestic hot water (DHW) recirculation system is to decrease the time spent waiting for the water to be delivered at acceptable temperatures when called for and also decrease the subsequent water consumption. The research detailed in this paper considered whether it is necessary to continuously run these recirculation pumps, as is general practice, or whether it is possible to reduce DHW system energy consumption by operating these pumps with some type of control strategy. Three different control strategies were evaluated by employing detailed monitoring. The different operating modes were: (a) base case (continuous operation), (b) shutdown during the overnight period, (c) shutdown during the peak morning and evening periods, and (d) cycling by a return line aquastat set at 110°F (61°C). In order to accomplish the research, six sites each had an aquastat installed onto the DHW return line and a programmable timeclock wired into the pump. The analysis identifies the relative energy use for each of the strategies during four round-robin rounds of two weeks each during the spring, summer, fall, and winter periods. When compared to the base case, (pump running 24 hours per day), Strategy B saves an average of 6%, Strategy C saves 6%, and Strategy D saves 11% of the DHW portion of a building's DHW energy requirements annually. This is significant in that for Strategy D, this translates into a savings of 4% of the building's total annual fuel bill. All of the control strategies evaluated were simple and employed low-cost devices (under $250 installed), which should help in achieving an extremely large implementation rate for the control strategy recommended. Tenant water quality survey questionnaires show that there was always an acceptable level of satisfaction, regardless of system control strategy.

Units: Dual


File Size : 1 file , 3.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 17
Product Code(s) : D-7617
Published : 1999

History


Related products


Best-Selling Products

DOXPUB 02-0001-SOP
Published Date: 08/01/2007
Recovery of Cryopreserved Cells
DOXPUB 02-0002-SOP
Published Date: 08/01/2007
Removal of Adherent Cells from Tissue Culture Flasks Using Trypsin/EDTA Solution
$4.2
DOXPUB 02-0003-SOP
Published Date: 08/01/2007
Assembly, Standardization, Sterilization and Inoculation of the Cell-Pharm Hollow Fiber Bioreactor for Antibody Production
$20.7
DOXPUB 02-0006-SOP-1.0
Published Date: 11/01/2004
Concentration of Bulk Antibody
$60
DOXPUB 02-0006-SOP
Published Date: 08/01/2007
Concentration of Bulk Antibody
$14.7
DOXPUB 02-0007-SOP
Published Date: 08/01/2007
Cell Culture Fluid Waste Disposal
$5.7