Coupling of Air Multizone and Thermal Multizone Models in Modelica PDF

Coupling of Air Multizone and Thermal Multizone Models in Modelica PDF

Name:
Coupling of Air Multizone and Thermal Multizone Models in Modelica PDF

Published Date:
2021

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.5
Need Help?
Building simulations are used to investigate building performance and design the building systems optimally. In particular, the air exchange between zonesand with the environment has a pivotal role inmodernventilation system design. Nevertheless, the model of the airflow becomes difficult for the modeler, motivated by the complexity of the grid that has to be modeled. IDEAS, a Modelica library, includes components for thermal multi-zone models of buildings as well as models for heating, ventilation, air conditioning and other elements that interact in the same model. The actual version, however, does not include proper components to model airflows in anefficient way. The simulatedair includes humidity and several trace substances, but the detailed transportation of those substances between the zones currently does not exist in the standard components. The purpose of this paper is twofold. At first, the article intends to describe the development of new components that will be used to implement the air multi-zone model into the existing thermal multi-zone model in IDEAS. The second goal is to integrate the newly developed components with the actual components of the library to share parameters that are needed to generate a grid of air pressure, reducing the modeling steps. The developed components are based on the pressure difference of the connected elements and include vertical air shafts, orifices, infiltration defined by the effective air leakage area, windows and doors.Keywords: Modelica, IDEAS library,building simulations,Multi-zone airflow, contaminant transport

Citation: IAQ 2020: Indoor Environmental Quality


File Size : 1 file
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-IAQ-20-C-10
Published : 2021

History


Related products


Best-Selling Products

prNS 2964
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polyethylene (PE) for underground non-pressure systems for drainage and sewerage
prNS 2965
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of polypropylene (PP) for underground non-pressure systems for drainage and sewerage
prNS 2966
Published Date: 10/24/2000
Plastics pipes - Pipes and fittings with structured wall of unplasticised poly(vinyl chloride) (PVC-U) for underground non-pressure systems for drainage and sewerage
prNS 2967
Published Date: 06/01/2001
Cable ducts of plastics with smooth solid wall pipe
prNS 2970
Published Date: 09/06/2004
Solid Wall cable ducting of thermoplastics for embedding
prNS 3563
Published Date: 07/01/2002
Ventilation for buildings - Design methodes for indoor climate