DA-00-12-1 -- Simplified Analysis of Building Thermal Storage Effects PDF

DA-00-12-1 -- Simplified Analysis of Building Thermal Storage Effects PDF

Name:
DA-00-12-1 -- Simplified Analysis of Building Thermal Storage Effects PDF

Published Date:
2000

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Whatever performance is offered by simulation software, simple performance characterization is very welcome at all stages of a building's life cycle. Building designers, contrac-tors, and operators need such characterization in order to interpret and to judge simulation as well as measurement results. It is common knowledge that most of building perturbations are not sinusoïdal and not even harmonic. But it is, nevertheless, very convenient to define each time function as the superposition of a time average and a (fictitious) oscillation around this average. This is the old fashion method of performing a manual calculation. The CIBSE "admittance procedure" was developed on such basis. This paper demonstrates how such very simplified analysis can help in detailed simulation. A practical example is presented, which deals with overheating risk calculation and fan coil sizing for an office building located in Brussels. Detailed simulation results are "translated" into two very synthetic building characteristics, which appear as very convenient references when having to compare different cooling strategies. Such analysis should also offer better possibilities of comparisons among problems encountered and among solutions selected in different projects.

Units: SI


File Size : 1 file , 450 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-7379
Published : 2000

History


Related products


Best-Selling Products

CAN/CSA 2/1/9075
Published Date: 03/01/2002
Information Technology - Database Languages - SQL - Part 2: Foundation (SQL/Foundation) (Adopted ISO/IEC 9075-2:1999, first edition, 1999-12-01)
$88.5
CAN/CSA 50001:11 (R2016)
Published Date: 06/01/2011
Energy management systems - Requirements with guidance for use (Adopted ISO 50001:2011, first edition, 2011-06-15)
$33
CAN/CSA 6.19-01 (R2016)
Published Date: 10/03/2001
Residential Carbon Monoxide Alarming Devices
$101.7
CAN/CSA 601.2.1-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Medical Electron Accelerators in the Range 1 MeV to 50 MeV (Adopted IEC 601-2-1:1981)
$14.1
CAN/CSA 601.2.11-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Adopted IEC 601- 2-11:1987)
$14.1
CAN/CSA 601.2.14-92
Published Date:
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Electroconvulsive Therapy Equipment (Adopted IEC 601-2-14:1989)
$11.1