Need Help?

PIV data were used to evaluate a renormalization group (RNG) k-e turbulence model of airflow in a full-scale test room (5.5 × 3.7 × 2.4 m [18.0 × 12.1 × 7.9 ft]) using FLUENT software. Three typical ventilation cases with ventilation rates of 0.12, 0.26, and 0.90 m3/s (250, 560, and 1900 cfm), which are equivalent to inlet Reynolds numbers of 2300, 5500, and 16,000, were evaluated for airflow patterns and air distribution. The RNG k-e turbulence model predicted airflow patterns, air distributions, and air velocities similar to PIV data throughout the room space. With the air ventilation rate increased from 0.12 to 0.26 m3/s (250 to 560 cfm), the agreement between the predicted and measured air velocities improved significantly. However, the deviation between prediction and measurement under air ventilation rates of 0.26 and 0.90 m3/s (560 and 1900 cfm) was not significant. In approximately 70% of the ventilation space, the normalized mean square error (NMSE) between the predicted and measured velocity magnitude was less than 0.25, which is an indicator of adequate model performance. This study showed that the RNG k-e turbulence model could be used to predict airflow under isothermal ventilation conditions in animal buildings with moderate ventilation rates, but it seems only applicable to room air with high Reynolds numbers.



Units: Dual


File Size : 1 file , 2.3 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-DA-07-038
Published : 2007

History


Related products


Best-Selling Products

PDI BPSGI
Published Date:
Basic Principles for Sizing Grease Interceptors
PDI G 101
Published Date: 03/01/2010
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance
PDI G 102
Published Date:
Testing and Certification for Grease Interceptors with FOG Sensing and Alarm Devices
PDI GGI-EM
Published Date: 01/01/2010
Guide To Grease Interceptors: Eliminating the Mystery
PDI MGO
Published Date:
Model Grease Ordinance
PDI MSREPFS
Published Date: 01/01/2009
MINIMUMSPACE REQUIREMENTS FOR ENCLOSED PLUMBING FIXTURE SUPPORTS