DA-13-C001 -- Performance Improvement of a Roof Top Air-Conditioning Unit by Refrigerant Circuitry Optimization PDF

DA-13-C001 -- Performance Improvement of a Roof Top Air-Conditioning Unit by Refrigerant Circuitry Optimization PDF

Name:
DA-13-C001 -- Performance Improvement of a Roof Top Air-Conditioning Unit by Refrigerant Circuitry Optimization PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

In this experiment-aided simulation study, we achieved the performance improvement of a Roof Top Unit (RTU) by optimizing an evaporator's refrigerant circuitry using evolutionary algorithms. The system used in this study was a 2-stage 7.5 Ton RTU with an air-to-refrigerant finned-tube evaporator consisting of 144 rifled tubes divided amongst 16 circuits. The RTU was designed to operate as an airto- air heat pump, but was modified with water-cooled condensers for the purpose of testing. Performance tests were conducted in an environmental chamber in line with AHRI standard 340/360 (2007) by maintaining the liquid line saturation temperature and subcooling from the manufacturer's test data by adjusting the condenser water flow rate and temperature. We measured the capacity of the original design included in the RTU to be 26.4 kW (90 100 Btu/h).

We also measured the in-situ air velocity profile under test condition using Particle Image Velocimetry (PIV), a non-intrusive, laserbased technique. The results of the PIV measurements uncovered several non-uniformities in the air velocity profile due to the blower location, the condensation drip tray, the placement of the air filter racks, and the position and orientation of the heat exchanger within the unit. The measurements showed that the range of air velocities passing through the heat exchanger varied from 0.5 m/s (1.64 ft/s) to 3.0 m/s (9.84 ft/s), with the integrated average of the measurements being 1.75 m/s (5.74 ft/s). We simulated the performance of the original evaporator operating with the measured air velocity profile using NIST's heat exchanger program, EVAP-COND. We matched the simulation results to the measured data by selecting appropriate correction factors for the refrigerant heat transfer coefficient, refrigerant pressure drop, and air-side heat transfer coefficient. We then used this model to optimize the evaporator circuitry using the evolutionary algorithm based module embedded in the program. The optimization process resulted in a design with a simulated capacity of 28.5 kW (97 200 Btu/h), nearly 8% higher than the original design.


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-DA-13-C001
Published : 2013

History


Related products


Best-Selling Products

GPA 101-43
Published Date: 01/01/1994
Standard Compression and Charcoal Tests for Determining the Natural Gasoline Content of Natural Gas
$13.5
GPA 1167-83
Published Date: 1983
GPA Glossary - Definition of Words and Terms Used in the Gas Processing Industry
$16.5
GPA 181-86
Published Date: 01/01/1986
Tentative Reference Bulletin Heating Value as a Basis for Custody Transfer of Natural Gas
$19.5
GPA 194-94
Published Date: 1994
Tentative NGL Loading Practices
$16.5
GPA 2103-20 Errata (July 2021)
Published Date: 2021
Errata (July 2021) to Method for the Analysis of Natural Gas Condensate Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography
Free Download
GPA 2103-20
Published Date: 2020
Method for the Analysis of Natural Gas Condensate Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography
$16.5